XX190-10-XX Pilot Select
Administration
•
15
Note: Receiver Number setting is only displayed when the event type is Preset.
Receiver Number
Preset numbers are not unique within the CCTV system. For example, every receiver might include ten
presets numbered 01 to 10. Therefore, in order to identify a particular preset position, both preset number and
receiver number must be specified.
Settings:
001 to 256
Keys:
Numeric keypad’s + (plus) key or - (minus) key
Set Triggered Events
Three triggered event types are programmable: Presets, Tours and Salvos. Unlike a timed event, which
activates at a specified time of day, triggered events activate when a specified V1200X-IA or V1300X-IA input
is activated. For example, an X-IA alarm input may be connected to a switch that is used by operators to
activate a specified tour. The Program Trigger Events screen for this example would be defined with Input
Number as 001, Event Type as Tour, Pattern/Nmbr as 001 and Monitor Nmbr as 02 (the Monitor Number
setting is only used for monitor tours, not salvo tours). If an operator activated the switch, monitor tour 001
would begin on monitor 02. Note that even though the alarm interface device is used, triggered events do not
activate alarms. The Set Externally Triggered Events screen defines which X-IA inputs will be used as
triggered events and the Edit Alarm Call-Up screen defines which X-IA inputs will be used for alarms.
Enter “1” to enable X-IA inputs as triggered events or “2” to define the functionality of the triggered events.
Menu Path: Main Menu
→
Administration
→
Set Triggered Events
SET EXTERNALLY TRIGGERED
EVENTS
1) SET TRGR INPUTS
2) PROGRAM TRGR EVENTS
ENTER SELECTION
ESC - PREVIOUS MENU