VBM-1400 Broadband Modulator Installation and User’s Guide
Initial Set Up and Configuration
Rev. 002
1018360
3-3
3.3.1.4.1
TX Power Detect
Shows a relative transmit power level as seen by the power detect
circuit.
3.3.1.5 Transmit
Shows and sets the current transmit status (On/Off).
If desired, change the setting of the transmit signal by pressing the
ENTER key and using the up/down cursor keys, change the setting as
desired. When the desired setting is shown on the display, press the
ENTER key again to enter the parameter into memory.
3.3.1.6 Spectrum
Shows and sets the current IF spectrum status (Normal or Inverted).
If desired, change the setting of the Spectrum by pressing the ENTER
key and using the up/down cursor keys, change the setting as desired.
When the desired setting is shown on the display, press the ENTER key
again to enter the parameter into memory.
3.3.1.7 Carrier
Shows and sets the current carrier method (Normal or CW).
If desired, change the setting of the Carrier by pressing the ENTER key
and using the up/down cursor keys, change the setting as desired.
When the desired setting is shown on the display, press the ENTER key
again to enter the parameter into memory.
3.3.1.8 Symbol Rolloff
Shows and sets the current symbol rolloff (alpha) value.
If desired, change the setting of symbol rolloff value by pressing the
ENTER key and using the cursor keys, change the setting as desired.
When the desired setting is shown on the display, press the ENTER key
again to enter the parameter into memory.
3.3.1.9 Modulation Type
Shows and sets the current modulation type.
If desired, change the setting of the modulation type by pressing the
ENTER key and using the cursor keys, change the setting as desired.
When the desired setting is shown on the display, press the ENTER key
again to enter the parameter into memory.
3.3.2 Interface
Parameters
Interface related parameters are displayed and set from the INTERFACE
MENU as described in the following paragraphs.
3.3.2.1 Interface Type
Shows and sets the current interface type.
If desired, change the interface type setting by pressing the ENTER key
and using the cursor keys, change the setting as desired. When the
desired setting is shown on the display, press the ENTER key again to
enter the parameter into memory.
Note Before changing the
interface type, first
disconnect the cables at J1
and/or J2, change the
interface type, and then
reconnect J1 and/or J2.
Содержание VBM-1400
Страница 2: ......
Страница 4: ......
Страница 5: ...Broadband Modulator VBM 1400 Installation and User s Guide ...
Страница 6: ......
Страница 10: ......
Страница 12: ...VBM 1400 Broadband Modulator Installation and User s Guide 1018360 Rev 002 ii ...
Страница 14: ...VBM 1400 Broadband Modulator Installation and User s Guide 1018360 Rev 002 iv ...
Страница 16: ...VBM 1400 Broadband Modulator Installation and User s Guide 1018360 Rev 002 vi ...
Страница 54: ...VBM 1400 Broadband Modulator Installation and User s Guide Remote Control 1018360 Rev 002 4 12 ...
Страница 68: ...VBM 1400 Broadband Modulator Installation and User s Guide Reshipment 1018360 Rev 002 7 2 ...
Страница 70: ...VBM 1400 Broadband Modulator Installation and User s Guide VBM 1400 Parameter Worksheet 1018360 Rev 002 A 2 ...
Страница 76: ...VBM 1400 Broadband Modulator Installation and User s Guide Glossary 1018360 Rev 002 C 4 ...
Страница 78: ...VBM 1400 Broadband Modulator Installation and User s Guide Index 1018360 Rev 002 D 2 ...
Страница 79: ...VBM 1400 Broadband Modulator Installation and User s Guide Drawings Rev 002 1018360 E 1 Appendix E Drawings ...
Страница 80: ...VBM 1400 Broadband Modulator Installation and User s Guide Drawings 1018360 Rev 002 E 2 ...