3
Dear customer,
We thank you that you have bought VULCANUS automatic solid fuel boiler and thus having shown
your confidence in VIADRUS a.s..
For you to get used to a correct way of handling your new product from the beginning, please read at
first this manual for usage (mainly chapter no. 6 – Boiler operation by user, chapter no. 7 – Important
cautions and chapter no. 8 – Maintenance). Please follow the bellow stated information at once – and
respect the producer´s, eventually assembly company´s which installed the boiler, instructions to be
provided a longterm failure-free boiler operation to your satisfaction.
1.
Boiler usage and advantages
The hot-water automatic boiler VULCANUS for solid fuel is designated first of all for heating the houses,
weekend houses, small premises, ect.
Boiler advantages:
•
automatic boiler operation, equithermal control
•
possibility of HW heating
•
mechanical fuel fedd from inbuilt reservoir
•
simple, time non-consuming boiler attendance and maintenance
•
low operating costs
•
high efficiency
2.
Boiler technical data
Tab. no. 1 Boiler dimensions, technical parameters
Size
4 sect.
5 sect.
6 sect.
7 sect.
Boiler weight
- small reservoir
kg
465
517
569
621
- large reservoir
kg
496
547
598
649
Water space volume
dm
3
60
71,9
83,8
95,8
Diameter of smoke socket
mm
156
Fuel reservoir capacity – small
dm
3
269
Fuel reservoir capacity – large
dm
3
528
Boiler dimensions (including small fuel reservoir):
width x depth x height
mm
See fig. no. 1
Boiler dimensions (including large fuel reservoir):
width x depth x height
mm
See fig. no. 1
Filling hole dimensions – small reservoir
mm
422 x 545
Filling hole dimensions – large reservoir
mm
422 x 1210
Boiler degree acc. to EN 303 - 5
-
3
Working water overpressure
bar (kPa)
2,5 (250)
Testing water overpressure
bar (kPa)
5 (500)
Recommended operating temperature of heating
water
°C
50 – 85
65 – 85
Minimum return water temperature
°C
45
50
Boiler hydraulic loss
mbar
0,72
0,96
1,32
1,59
Noise level
dB
Doesn´t exceed level 65 dB (A)
Chimney draught
Pa
15 –20
20 –25
Boiler connections – heating water
Js
G 2”
– return water
Js
G 2”
Connecting voltage
1/N/PE 230 V AC 50 Hz TN - S
Electric input
W
100
Electric coverage
IP 44
Содержание VULCANUS