4
Tab. no. 2a) Thermal technical parameters of the boiler during combustion of brown coal
Size
4 sect.
5 sect.
6 sect.
7 sect.
Nominal output
kW
20
25
30
35
Regulated output
kW
6 - 20
7,5 - 25
9 - 30
10,5 - 35
Fuel consumption at nominal output
kg.h
-1
4,5
5,6
6,65
7,65
Fuel consumption at minimum output
kg.h
-1
1,4
1,7
2,02
2,32
Fuel consumption in upkeep regime
kg.h
-1
0,1
0,1
0,1
0,1
Fuel value
MJ.kg
-1
19,17
19,17
19,17
19,17
Burning time at nominal output – small
reservoir
h
36 h 15 min
29 h 10 min
24 h 30 min
21 h 15 min
Burning time at nominal output – large reservoir
h
71 h 30 min
57 h 20 min
48 h 15 min
42 h
Efficiency
%
up to 83,1
up to 85
up to 87
up to 89
Flue gas temperature
°C
115 – 195
100 – 180
95 – 170
90 – 160
Flue gas mass flow at outlet
kg.s
-1
0,007 – 0,015 0,009 – 0,019 0,011 – 0,022 0,013 – 0,025
Tab. no. 2b) Thermal technical parameters of the boiler during combustion of black coal
Size
4 sect.
5 sect.
6 sect.
7 sect.
Nominal output
kW
20
25
30
35
Regulated output
kW
6 - 20
7,5 - 25
9 - 30
10,5 - 35
Fuel consumption at nominal output
kg.h
-1
3,4
4,21
5
5,8
Fuel consumption at minimum output
kg.h
-1
1,03
1,28
1,52
1,76
Fuel consumption in upkeep regime
kg.h
-1
0,13
0,13
0,13
0,13
Fuel value
MJ.kg
-1
25,1
25,1
25,1
25,1
Burning time at nominal output – small
reservoir
h
45 h 10 min
36 h 30 min
30 h 35 min
26 h 25 min
Burning time at nominal output – large reservoir
h
88 h 40 min
71 h 35 min
60 h 15 min
52 h
Efficiency
%
up to 84,2
up to 85
up to 86
up to 87
Flue gas temperature
°C
110 – 195
90 – 170
85 – 165
80 – 150
Flue gas mass flow at outlet
kg.s
-1
0,007 – 0,014 0,010 – 0,017 0,012 – 0,021 0,014 – 0,024
Tab. no. 2c) Thermal technical parameters of the boiler during combustion of wood pellets
Size
4 sect.
5 sect.
6 sect.
7 sect.
Nominal output
kW
20
25
30
35
Regulated output
kW
6 - 20
7,5 - 25
9 - 30
10,5 - 35
Fuel consumption at nominal output
kg.h
-1
4,85
6,06
7,26
8,47
Fuel consumption at minimum output
kg.h
-1
1,5
1,84
2,21
2,57
Fuel consumption in upkeep regime
kg.h
-1
0,35
0,35
0,35
0,35
Fuel value
MJ.kg
-1
17
17
17
17
Burning time at nominal output – small
reservoir
h
27 h 10 min
21 h 45 min
18 h 10 min
15 h 30 min
Burning time at nominal output – large reservoir
h
53 h 20 min
42 h 40 min
35 h 35 min
30 h 30 min
Efficiency
%
up to 87,3
up to 87,4
up to 87,5
up to 87,5
Flue gas temperature
°C
95 – 175
90 – 165
90 – 160
85 – 145
Flue gas mass flow at outlet
kg.s
-1
0,007 – 0,015 0,009 – 0,018 0,010 – 0,022 0,012 – 0,025
! Important notice:
The above mentioned values vary according to the type, quality and moisture of the fuel used.
Therefore there may be necessary corrections at setting of feeding time (proportion of fuel feeding
and fuel afterburning time). For example, if there occur the sliver parts of fuel on the fire grate and in
the ash pan, it is evident, that the speed of feeding is higher than the speed of afterburning, in this
case it is necessary to decrease the feeding cycle.
Specified fuel parameters – fuel which was tested by SZÚ:
•
Water content
max. 12 % (hard coal, wood pellets),
max. 20 % (lignite)
•
Volatile combustible content
28 - 40 %
•
Ash deformation temperature by melting
> 1150 °C
•
Low agglutinating power
•
Low creeping