52
P 171
Feeder Y1 hard coal(
Č
U)
[s]
Setting the feeder standstill time for
Č
U fuel relating to 0% output
P 172
Feeder X2 hard coal
[%]
It regards the percentage value of output.
Value 33 represents 33% output and feeder standstill time of parameter 173 is assigned to this value.
Note: This parameter cannot be changed
P 173
Feeder Y2 hard coal
[s]
Setting the feeder standstill time for
Č
U fuel relating to 33% output
P 174
Feeder X3 hard coal
[%]
It regards the percentage value of output.
The value 66 represents 66% output and feeder standstill time of parameter 175 is assigned to this
value. Note: This parameter cannot be changed
P 175
Feeder Y3 hard coal
[s]
Setting the feeder standstill time for
Č
U as the fuel relating to 66% output
P 176
Feeder X4 hard coal
[%]
It regards the percentage value of output.
The value 100 represents 100% output and feeder standstill time of parameter 177 is assigned to this
value. Note: This parameter cannot be changed
P 177
Feeder Y4 hard coal
[s]
Setting the feeder standstill time for
Č
U as the fuel relating to 100% output
P 178
Feeder runtime in the attenuation regime– hard coal
[s]
Setting the feeder runtime in the attenuation regime for
Č
U as the fuel
P 179
Standstill time(delay) of feeder in the attenuation – hard coal
[min.]
Standstill time of the feed screw in the attenuation regime for
Č
U as the fuel
P 200
Ventilator X1 hard coal
[%]
It regards the percentage value of ventilator output
The value 0 represents min. ventilator output and actual ventilator output of parameter 201 is assigned
to this value. Note: This parameter cannot be changed
P 201
Ventilator Y1 hard coal
[%]
Setting the actual ventilator output for
Č
U as the fuel relating to 0% ventilator output
P 202
Ventilator X2 hard coal
[%]
It regards the percentage value of ventilator output
The value 33 represents 33% ventilator output and actual ventilator output of parameter 203 is
assigned to this value.Note: This parameter cannot be changed
P 203
Ventilator Y2 hard coal
[%]
Setting the actual ventilator output for
Č
U as the fuel relating to 33% ventilator output
P 204
Ventilator X3 hard coal
[%]
It regards the percentage value of ventilator output
The value 66 represents 66% ventilator output and actual ventilator output of parameter 205 is
assigned to this value. Note: This parameter cannot be changed
P 205
Ventilator Y3 hard coal
[%]
Setting the actual ventilator output for
Č
U as the fuel relating to 66% ventilator output
P 206
Ventilator X4 hard coal
[%]
It regards the percentage value of ventilator output
The value 100 represents 100% ventilator and actual ventilator output of parameter 207 is assigned to
this value.Note: This parameter cannot be changed
P 207
Ventilator Y4 hard coal
[%]
Setting the actual ventilator output for
Č
U as the fuel relating to 100% ventilator output
P 208
Ventilator slowing-down in the attenuation regime– hard coal
[s]
Setting the ventilator slowing-down in the attenuation regime against the feeder runtime in the
attenuation regime
P 209
Ventilator output in the attenuation regime – hard coal
[%]
Setting the ventilator output in the attenuation regime
Содержание VULCANUS
Страница 1: ...Hercules U26 Návod k obsluze VULCANUS MANUAL FOR BOILER OPERATION AND INSTALLATION ...
Страница 19: ...19 5 2 2 Shells assembly Fig no 12 Boiler shell ...
Страница 27: ...27 Fig no 18 VULCANUS boiler left hand design ...
Страница 70: ...70 ...
Страница 72: ...72 Update 17 2013 GB model 2013 ...