53
P 210
Feeder X1 pellets
[%]
It regards the percentage value of output.
The value 0 represents min. output and feeder standstill time of parameter 211 is assigned to this
value.Note: This parameter cannot be changed
P 211
Feeder Y1 pellets
[s]
Setting the feeder standstill time for pellets as the fuel relating to 0% output
P 212
Feeder X2 pellets
[%]
It regards the percentage value of output.
The value 33 represents 33% output and feeder standstill time of parameter 213 is assigned to
this value.Note: This parameter cannot be changed
P 213
Feeder Y2 pellets
[s]
Setting the feeder standstill time for pellets as the fuel relating to 33% output
P 214
Feeder X3 pellets
[%]
It regards the percentage value of output.
Value 66 represents 66% output and feeder standstill time of parameter 215 is assigned to this
value. Note: This parameter cannot be changed
P 215
Feeder Y3 pellets
[s]
Setting the feeder standstill time for pellets as the fuel relating to 66% output
P 216
Feeder X4 pellets
[%]
It regards the percentage value of output.
Value 100 represents 100% output and feeder standstill time of parameter 21 is assigned to this
value 7. Note: This parameter cannot be changed
P 217
Feeder Y4 pellets
[s]
Setting the feeder standstill time for pellets as the fuel relating to 100% output
P 218
Feeder runtime in the attenuation – pellets
[s]
Setting the feeder runtime in the attenuation regime for pellets as the fuel
P 219
Standstill time(delay) of feeder in the attenuation – pellets
[min.]
Standstill time of the feed screw in the attenuation regime for pellets as the fuel
P 220
Ventilator X1 pellets
[%]
It regards the percentage value of ventilator output
The value 0 represents min. ventilator output and the actual ventilator output of parameter 221 is
assigned to this value. Note: This parameter cannot be changed
P 221
Ventilator Y1 pellets
[%]
Setting the actual ventilator output for pellets as the fuel relating to 0% ventilator output
P 222
Ventilator X2 pellets
[%]
It regards the percentage value of ventilator output
Value 33 represents 33% ventilator output and the actual ventilator output of parameter 223 is
assigned to this value. Note: This parameter cannot be changed
P 223
Ventilator Y2 pellets
[%]
Setting the actual ventilator output for pellets as the fuel relating to 33% ventilator output
P 224
Ventilator X3 pellets
[%]
It regards the percentage value of ventilator output
Value 66 represents 66% ventilator output and the actual ventilator output of parameter 225 is
assigned to this value at parameter 225. Note: This parameter cannot be changed
P 225
Ventilator Y3 pellets
[%]
Setting the actual ventilator output for pellets as the fuel relating to 66% ventilator output
P 226
Ventilator X4 pellets
[%]
It regards the percentage value of ventilator output
Value 100 represents 100% ventilator output and the actual ventilator output of parameter 227 is
assigned to this value. Note: This parameter cannot be changed
P 227
Ventilator Y4 pellets
[%]
Setting the actual ventilator output for pellets as the fuel relating to 100% ventilator output