23
-
Apply a reasonable amount of new sealant to the flange seating surface. Connect the fuel feeder with the fuel
tank (fixtures are as follows: 4 pc screw M8 x 25, 4 pc washer 8.4 and 4 pc nut M8).
-
Connect the emergency fire-extinguishing equipment.
-
Connect the switchboard incl. consoles to the fuel tank.
-
Connect the components.
-
In case the conversion was done already after the primary installation, the length of cables must be trimmed as
needed and the old mastic from the grate and the fuel feeder flange must be removed.
1.
Switchboard
2.
Nut M6 (4 pc)
3.
Flexible washer 6.4 (4 pc)
4.
Mudguard washer 6.4 (4 pc)
5.
Screw M6 x 16 (4 pc)
6.
Nut M8 (4 pc)
7.
Washer 8.4 (8 pc)
8.
Screw M8 x 20 (4 pc)
9.
Fuel feeder
10. Screw M10 x 20 (4 pc)
11. Washer 10.5 (4 pc)
12. Nut M10 (4 pc)
13. Fuel tank
Fig.
№
. 17
Boiler conversion from the right-hand to left-hand design – disconnection of the fuel tank and
the fuel feeder