11
e) to the power supply network
CSN 33 0165
Electrical regulations. Identification of conductors by colours or numerals.
Procedure provisions
CSN 33 1500
Electrical regulations. Revision of electrical equipments.
CSN 33 2000-1 ed. 2
Low-voltage electrical installations – Part 1: Fundamental principles, assessment of
general characteristics, definitions.
CSN 33 2000-4-41 ed. 2
Low voltage electrical installations - Part 4- 41: Protection for safety - Protection
against electric shock
CSN 33 2000-5-51 ed. 3
Electrical installations of buildings – Part 5-51: Selection and erection of electrical
equipment – Common rules
CSN 33 2130 ed. 2
Low-voltage electrical installations – Internal electric distribution lines
CSN 33 2180
Electrical regulations. Connection of electric instruments and appliances.
CSN 34 0350 ed. 2
Safety requirements for flexible cords and cables
EN 60079-10-1
Explosive atmospheres – Part 10-1: Classification of areas – Explosive gas
atmospheres
EN 60079-14 ed.3
Explosive atmospheres - Part 14: Electrical installations design, selection and
erection
EN 60252-1 ed. 2
Capacitors for AC motors – Part 1: In general – Design, testing, dimensioning –
Safety requirements – Instructions for installation and operation.
EN 60335-1 ed.2
Electric appliances for household and similar purposes – Safety – Part 1: General
requirements
EN 60335-2-102
Electric appliances for household and similar purposes – Safety – Part 2-102:
Special demands on appliances containing the electric connections and burning the
gas, oil and solid fuels
EN 60445 ed. 4
Basic and safety principles for man-machine interface, marking and identification –
Identification of equipment terminals, conductor terminations and conductors
EN 61000-6-3 ed. 2
Electromagnetic compatibility (EMC) - Part 6-3: Generic standards – Emission
standard for residential, commercial and and light industrial environments.
EN 61000-3-2 ed. 3
Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current
emissions (equipment input current
≤
16 A per phase).
EN 61000-3-3 ed. 2 (ed. 3)
Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage
changes, voltage fluctuations and flicker in public low-voltage supply systems, for
equipment with rated current
≤
16 A per phase and not subject to conditional
connection.
4.2
Placement options
The boiler is equipped with the movable mains supply and plug. According to EN 60 335–1 ed. 2
Art. 7.12.4, the boiler must be positioned in such a way that the plug is accessible.
The boiler positioning in the living space (including corridors) is prohibited!
When installing and using the boiler, all requirements of CSN 06 1008 must be complied with.
The boiler positioning with regard to fire regulations:
1. Placement on the floor made of incombustible material
−
place the boiler on a fireproof and heat-insulating base exceeding the boiler dimensions on the sides by 20
mm;
−
if the boiler is installed in a cellar, we recommend to install it on a substructure at least 50 mm high. The
boiler must be installed straight, any possible inequalities of the substructure are eliminated by means of
adjustable foot (see Fig. 13)
2. Safe distance from flammable materials:
−
when installing and operating the boiler it is necessary to keep the safe distance of 200 mm from flammable
materials with combustibility grade A1, A2, B and C (D);
−
for easily flammable materials with combustibility grade E (F), which burn quickly and by themselves also
after the ignition source removal (e.g. paper, cardboard, asphalt and tar boards, wood and fibreboards,
plastics, flooring materials), the safe distance is doubled, that is 400 mm;
−
the safe distance is to be doubled also when the fire reaction class is not proven.