Site preparation
2
-
4
Chapter 2: Before You Begin
Wave Server Installation Guide
Physical specifications
Wave IP 500
Wave IP 2500
Environmental requirements
For the Wave Server to operate properly, the environmental specifications in the following table
must be met
All models.
Dimensions
2.6 inches high x 17.6 wide x 13.8 inches deep (6.4 x 44.7 x 34.9 cm), 1.5U
rack height)
Weight
14 pounds (6.4 kg)
Dimensions
Base unit: 4.4 inches high x 17.6 wide x 17.9 deep (11.1 x 44.7 x 45.5 cm),
2.5U rack height
EXU: 2.6 inches high x 17.6 wide x 17.9 deep (6.4 x 44.7 x 45.5 cm),
1.5U rack height
Weight
Base unit: 26 pounds (11.8 kg)
EXU: 19 pounds (8.6 kg)
Requirement
Value or range
Operating temperature
32° to 104° F (0° to 40° C)
Operating humidity
80% maximum relative humidity, noncondensing
Operating altitude
Up to 10,000 ft (3050 m)
Storage temperature
-4° to 140° F (-20° to 60° C)
Storage humidity
85% maximum relative humidity, noncondensing
Clearance for servicing
Minimum 24 in (61 cm) front and back
Clearance for cooling
Minimum 4 in (10 cm) on all sides
AC power requirements,
E1 internal power supply
Base unit: 100-240 VAC, 50/60 Hz, 9A
EXU: 6A
Release 4.0
June 20, 2013
Содержание WAVE IP 2500
Страница 1: ...Wave Server Installation Guide Wave 4 0 Wave Server Installation Guide Release 4 0 June 20 2013 ...
Страница 4: ...Release 4 0 June 20 2013 ...
Страница 16: ...Release 4 0 June 20 2013 ...
Страница 34: ...Release 4 0 June 20 2013 ...
Страница 94: ...Release 4 0 June 20 2013 ...
Страница 112: ...Release 4 0 June 20 2013 ...
Страница 200: ...Release 4 0 June 20 2013 ...
Страница 214: ...Release 4 0 June 20 2013 ...