VII. Venting
D. Design Requirements Unique to Split Vent Systems (continued)
Table 7.21: Summary of Split Vent System Options
Option #
11
12
13
14
15
16
Illustrated in Figure
7.22
7.22
7.22
7.22
7.23, 7.24
7.23, 7.24
Pipe Penetration
Through Structure
Vent
Roof
Roof
Roof
Roof
Roof
Roof
Intake
Wall
Wall
Wall
Wall
Wall
Wall
Material
Vent
CPVC/PVC
(Note 2)
DuraVent
PolyPro
(Rigid)
Selkirk
Polyflue
Centrotherm
InnoFlue SW
DuraVent
PolyPro
(Rigid/Flex)
Selkirk Polyflue
(Rigid/Flex)
Intake
PVC
PVC
PVC
PVC
PVC
PVC
Nominal Diameter
Vent
3”
3”
3”
3”
3”
3”
Intake
3”
3”
3”
3”
3”
3”
Min Equivalent Vent Length:
Models
135
48”
48”
48”
48”
48”
48”
150
52”
52”
52”
52”
52”
52”
180
52”
52”
52”
52”
52”
52”
Max Equivalent Vent Length (Note 1):
Models
135
135ft
135ft
135ft
135ft
135ft
135ft
150
135ft
135ft
135ft
135ft
135ft
135ft
180
135ft
135ft
135ft
135ft
135ft
135ft
Rigid Vent Terminals
Vent
Coupling
w/Screen
3PPS-12B or
3PPS-36B
w/Screen
3PF-10UV
or 3PF-
39UV
w/Screen
ISEP03 or
ISEP0339 w/
Screen
Not Permitted
Intake
90 Elbow
w/Screen
90 Elbow
w/Screen
90 Elbow
w/Screen
90 Elbow w/
Screen
Flex Termination
& Components
(Masonry Chimney
Chase) (Note 3)
Vent
Not Permitted
3PPS-FK
3PPS-FLEX**
3PF-FLEX-KIT
3PF-FLEX
Intake
90 Elbow
w/Screen
90 Elbow
w/Screen
Flex Termination
& Components
(B-Vent Chimney
Chase)
Vent
Not Permitted
3PPS-VFT
3PPS-BF*
3PPS-FLEX**
3PF-10UV or
3PF-39UV
w/Screen
3PF-BVSC
(Note 3)
Intake
90 Elbow
w/Screen
90 Elbow
w/Screen
* Specify size of B vent (e.g. 3PPS-BV6 is for use with 6” B vent).
** Specify length in feet.
Note 1: Max vent lengths shown also apply to the intake. Flex vent reduces the maximum allowable vent length in some
applications. See equivalent lengths for flex vent shown in Table 7.14 and sizing example on page 32.
Note 2: First 30” plus first exhaust elbow are CPVC.
Note 3: See Polyflue installation manual for gaskets, spacers and other required vent components.
All vertical terminals require compatible roof flashing and storm collars.
Содержание K2WTC-135
Страница 10: ...10 107774 02 4 18 Figure 4 1 Minimum Clearances To Combustible Construction IV Locating the Boiler continued...
Страница 12: ...12 107774 02 4 18 Figure 5 1 Wall Layout Mounting Hole Location V Mounting The Boiler continued...
Страница 74: ...74 107774 02 4 18 Figure 9 2 Piping Method 1 Near Boiler Piping Heating Only IX System Piping continued...
Страница 76: ...76 107774 02 4 18 Figure 9 5 Piping Method 1 Near Boiler Piping Shaded Boiler Loop IX System Piping continued...
Страница 81: ...81 107774 02 4 18 X Domestic Hot Water Piping continued Figure 10 1 Domestic Hot Water Piping...
Страница 87: ...87 107774 02 4 18 Figure 11 6 J3 Field Wiring Figure 11 5 4 20 mA EMS Field Wiring XI Wiring continued...
Страница 89: ...89 107774 02 4 18 XI Wiring continued...
Страница 90: ...90 107774 02 4 18 Figure 11 8 Internal Wiring Connections Diagram XI Wiring continued...
Страница 92: ...92 107774 02 4 18 Figure 11 9 TACO SR504 or Equivalent Zone Panel Wiring Connection Diagram XI Wiring continued...
Страница 93: ...93 107774 02 4 18 Figure 11 10 Sage Zone Control Circulator Panel Wiring Connection Diagram XI Wiring continued...
Страница 101: ...101 107774 02 4 18 Lighting and Operating Instructions XII Start Up and Checkout continued...
Страница 142: ...142 107774 02 4 18 XVI Repair Parts continued...
Страница 145: ...145 107774 02 4 18 XVI Repair Parts continued...
Страница 148: ...148 107774 02 4 18 XVI Repair Parts continued...
Страница 150: ...150 107774 02 4 18 XVI Repair Parts continued...
Страница 152: ...152 107774 02 4 18 XVI Repair Parts continued 120 121 122 123 124 125 126 127...
Страница 159: ...159 107774 02 4 18 SERVICE RECORD DATE SERVICE PERFORMED...
Страница 160: ...160 107774 02 4 18 U S Boiler Company Inc P O Box 3020 Lancaster PA 17604 1 888 432 8887 www usboiler net...