XIII. Operation
E. Boiler Sequence Of Operation (continued)
2. Using The Display
The Control includes a touch screen LCD display. The user monitors and adjusts boiler operation by
selecting screen navigation “buttons” and symbols. The “Home Screen” and menu selections are shown
below. When no selection is made, while viewing any screen, the display reverts to the “Home Screen” after
4 minutes. The “Home Screen” provides boiler temperature, firing rate in BTU/hr, boiler status, efficiency
information and page links.
(Figure 13.6)
(Figure 15.1)
(Figure 13.9)
Figure 13.4: Home Screen Details
(Figure 13.8)
Figure 13.5: Screen Navigation
132 F
140 F
Active
Fault
100%
Boiler 1
>
<
Central Heat
Lockout
Supply
Rate
Status:
Setpoint
Priority:
Home
Improper settings or service
create risk of property
damage, injury, or death.
Adjust
180
F
Energy Save On
High Efficiency On
Help
Adjust
Central Heat
Status
Detail
i
kbtu
hr
80
Boiler 1
Menu Buttons
Information Symbol
Software revision
numbers.
Fault Indication
User is guided by
“blinking” touch buttons
to Help screens that
identify the problem.
Rate
Firing rate is displayed as
kbtu/hr input.
Demand Status
The reason or cause of the boiler demand is
displayed; Central Heat, Auxiliary Heat,
Domestic Hot Water, Sequencer Control (peer-
to-peer Demand) or Frost Protection. Warm
Weather Shutdown status is shown. “Standby’
is shown when no demand is present.
Energy Save On Indication
Outdoor Air Reset, DHW or setback have
lowered boiler water setpoint.
High Efficiency On Indication
Return temperature is low enough to allow
energy saving flue gas condensation.
Help
Fault correction & service contact
Detail
In depth view of operation
Status
“Walk through” operation
Adjust
Modify boiler operation
Close Symbol
The “Close” symbol returns to the display to previous menu or screen.
Repeatedly pressing the “Close” symbol will always return the display
to the “Home” screen.
Arrow Symbol
The “Arrow” symbol links together all screens in the selected group.
For example, repeated pressing the right “Arrow” symbol will rotate the
display around all the screens in the Status group. Using this feature the
user can review all the boiler status and adjustment mode screens
Fault Symbols
“Active Fault” and “Rate Limit” symbols provide a link to the cause of a
boiler fault or firing rate limit. The first boiler status screen provides an
overview of boiler operation including fault status.
Status Screen
132 F
140 F
100%
Boiler 1
>
<
Central Heat
Running
Supply
Rate
Status:
Setpoint
Priority:
Central
Heat
Auxiliary
Heat
Domestic
Hot Water
Outdoor
Reset CH
1-2
Fault
Status
Lockout
History
1-2
Sequencer
Setup
Zone Panel
Setup
Service Contact
>
<
>
<
Содержание K2WTC-135
Страница 10: ...10 107774 02 4 18 Figure 4 1 Minimum Clearances To Combustible Construction IV Locating the Boiler continued...
Страница 12: ...12 107774 02 4 18 Figure 5 1 Wall Layout Mounting Hole Location V Mounting The Boiler continued...
Страница 74: ...74 107774 02 4 18 Figure 9 2 Piping Method 1 Near Boiler Piping Heating Only IX System Piping continued...
Страница 76: ...76 107774 02 4 18 Figure 9 5 Piping Method 1 Near Boiler Piping Shaded Boiler Loop IX System Piping continued...
Страница 81: ...81 107774 02 4 18 X Domestic Hot Water Piping continued Figure 10 1 Domestic Hot Water Piping...
Страница 87: ...87 107774 02 4 18 Figure 11 6 J3 Field Wiring Figure 11 5 4 20 mA EMS Field Wiring XI Wiring continued...
Страница 89: ...89 107774 02 4 18 XI Wiring continued...
Страница 90: ...90 107774 02 4 18 Figure 11 8 Internal Wiring Connections Diagram XI Wiring continued...
Страница 92: ...92 107774 02 4 18 Figure 11 9 TACO SR504 or Equivalent Zone Panel Wiring Connection Diagram XI Wiring continued...
Страница 93: ...93 107774 02 4 18 Figure 11 10 Sage Zone Control Circulator Panel Wiring Connection Diagram XI Wiring continued...
Страница 101: ...101 107774 02 4 18 Lighting and Operating Instructions XII Start Up and Checkout continued...
Страница 142: ...142 107774 02 4 18 XVI Repair Parts continued...
Страница 145: ...145 107774 02 4 18 XVI Repair Parts continued...
Страница 148: ...148 107774 02 4 18 XVI Repair Parts continued...
Страница 150: ...150 107774 02 4 18 XVI Repair Parts continued...
Страница 152: ...152 107774 02 4 18 XVI Repair Parts continued 120 121 122 123 124 125 126 127...
Страница 159: ...159 107774 02 4 18 SERVICE RECORD DATE SERVICE PERFORMED...
Страница 160: ...160 107774 02 4 18 U S Boiler Company Inc P O Box 3020 Lancaster PA 17604 1 888 432 8887 www usboiler net...