Appendix C — Filter Manager Error/Status Codes
131
Filter Manager Error/Status Codes
-467
Invalid ClosedGOP setting in IBM Video Registry
table.
Check IBM Video Registry
table (see Appendix A).
-468
Invalid chroma setting in IBM Video Registry
table.
Check IBM Video Registry
table (see Appendix A).
-469
Embedded metadata is not supported.
-470
Invalid non-linear quantization setting.
Must be 0 or 1.
Check IBM Video Registry
table (see Appendix A).
-471
Invalid Concealment Vector setting. Must be 0 or
1. MUST set to 0 for low-bitrate SIF, or corrupted
macroblocking will occur.
Check IBM Video Registry
table (see Appendix A).
-472
Invalid DC Precision setting. Must be 8, 9, 10, or
11, with the value of 8 reserved exclusively for
SIF encodes. FilterManager will automatically
encode SIF with a DCPrecision of 8, regardless
of setting in Registry.
Check IBM Video Registry
table (see Appendix A).
-473
Invalid Intra-table flag.
Check IBM Video Registry
table (see Appendix A).
-474
Invalid aspect ratio. Must be square(1), 4x3 (2),
16x9 (3) or 2.21 x 1 (4).
Check IBM Video Registry
table (see Appendix A).
-475
Invalid audio bitrate supplied for main encode.
Must be 32000, 48000, 56000, 64000, 80000,
96000, 112000, 128000, 160000, 192000,
224000, 256000, 320000, or 384000.
Check IBM Audio Registry
table (see Appendix A).
-476
Invalid sample rate supplied for main encode.
Must be 32000, 441000, or 48000. If Ligos
encode is turned on, cannot be 32000.
Check IBM Audio Registry
table (see Appendix A).
-477
Invalid audio mode supplied for main encode.
Must be 0-Stereo, 1-Joint, 2-Dual, 3-Single.
Check IBM Audio Registry
table (see Appendix A).
-478
Invalid audio input supplied for main encode.
Must be analog, digital, or inactive.
Check IBM Audio Registry
table (see Appendix A).
-479
Invalid audio layer for main encode. We support
only layer 2.
Check IBM Audio Registry
table (see Appendix A).
Filter Manager Error/Status Codes (Continued)
Error Code
Meaning
Comments
Table C-1. Filter Manager Error/Status Codes (Continued)