114
Argus Encoder Family Version 2.6 API Developer’s Guide
Filter Manager Error/Status Codes
-13
Main storage component failed to stop, pause, or
resume.
Summary error message.
Check log for more descrip-
tive messages regarding sta-
tus of storage component.
-13
V_FIFO_UNDERFLOW
(Encoder chip error code)
A timeout occurred while
attempting to read data from
the encoder. Run encoder
diags, check the video
source.
-14
CineView Pro component failed on a stop.
May be locked up. Check log
for other error messages.
-14
V_FIFO_OVERFLOW
(Encoder chip error code)
A FIFO overflow was
detected when trying to read
data from the board. May be
the result of setting the
bitrate too high, given the
configuration of the system
and the nature of the
encode. Also, make certain
no other process is running
on the system at the time of
the encode.
-15
VTR component failed to cue, stop, pause, or
write adjustment to Registry.
Summary message. Check
log for other VTR-related
messages.
-15
V_FIFO_READ
(Encoder chip error code)
An error occurred while
attempting to read the video
FIFO. Run encoder diags,
check the video source.
-16
Storage component for elementary audio or
video stream failed to stop or resume.
Summary message. Should
occur only during elemen-
tary stream encode.
Filter Manager Error/Status Codes (Continued)
Error Code
Meaning
Comments
Table C-1. Filter Manager Error/Status Codes (Continued)