![background image](http://html1.mh-extra.com/html/vela/argus-2000-0370-2/argus-2000-0370-2_developers-manual_860581150.webp)
142
Argus Encoder Family Version 2.6 API Developer’s Guide
Filter Manager Error/Status Codes
-725
Real DLL directory is not registered.
-726
A filename was not supplied in the Real Registry.
Check the RealNetworks
Registry to be sure that a
file name was supplied. (For
EDL Editor, this name will be
generated based on the
main MPEG file name.).
-727
Mux failed to start.
Usually the result of an
audio or video board failure.
-728
Video input ended.
Video input stopped unex-
pectedly. Check for PAL/
NTSC or analog/digital con-
flict. Run diagnostics.
-729, -730
Audio input ended.
Audio input stopped unex-
pectedly. Check for PAL/
NTSC or analog/digital con-
flict. Run diagnostics
-731
Mux outpin error.
The application was unable
to send the muxed stream
to the output pin. Check
CPU/memory usage.
-732
Invalid VBR bit rate.
The average VBR bit rate
entered must be less than
the maximum bit rate.
-733
VBR not installed.
The application attempted to
run a VBR encode when the
VBR microcode has not
been installed.
-734
Invalid Mux mark-in.
The mark-in entered for the
Mux time-code adjustment
is invalid.
-800
User cancelled encode after cueing, but before
starting.
Shut down and restart the
application before attempt-
ing another encode.
Filter Manager Error/Status Codes (Continued)
Error Code
Meaning
Comments
Table C-1. Filter Manager Error/Status Codes (Continued)