![background image](http://html1.mh-extra.com/html/vela/argus-2000-0370-2/argus-2000-0370-2_developers-manual_860581137.webp)
Appendix C — Filter Manager Error/Status Codes
129
Filter Manager Error/Status Codes
-441
During elementary encode, video component
failed to pause.
-443
If a system, program, or transport stream is
selected as the mux type in the mux Registry, but
the mux-file-enabled flag is not set in the “Filter-
Mgr” Registry table, this error flag is set. Also, if
an elementary stream is selected as the mux type
in the mux Registry, but the video-file-enabled
flag is not set in the “FilterMgr” Registry, this
flag is set.
Check stream type in Mux
Registry, and compare it to
the file type enabled in the
FilterMgr Registry. See
Appendix A.
-444
Invalid mux file path name.
Make sure that the path-
name specified for the mux
file is present and writable.
-445
Invalid video file path name.
For an elementary-stream
encode, make sure that the
pathname specified for the
video file is present and
writable.
-446
Invalid audio file path name.
For an elementary stream
encode, make sure that the
pathname specified for the
audio file is present and
writable.
-448
Argus Registry failure.
Unable to open the
HKEY_CURRENT_USER path
Software\Vela Research\
Broadcast Argus. Check the
Registry.
-449
Unable to open the “IBM Video” Registry table.
-450
Unable to open the “IBM Audio” Registry table.
-451
Unable to open the “Mux” Registry table.
-452
Unable to open the “DualEnc” Registry table
-455
Unable to open the “VTR” Registry table.
Filter Manager Error/Status Codes (Continued)
Error Code
Meaning
Comments
Table C-1. Filter Manager Error/Status Codes (Continued)