Appendix C — Filter Manager Error/Status Codes
127
Filter Manager Error/Status Codes
-416
Ligos failed to create the video outpin or one of
the two audio outpins.
Make certain Vela_Pins is
registered.
-417
Failure setting up the Ligos software.
Make certain that Ligos
component (and Ligos
libraries) are properly
installed.
-418
Failure to open the Ligos encoder.
Make certain that Ligos
component (and Ligos
libraries) are properly
installed.
-419, -420
Error marshalling data into Ligos thread
(for callbacks).
-422, -423
Error opening the Ligos or codec Registry.
Use RegEdit and RegCtrlPnl
to check the existence and
state of the Ligos and codec
tables (See Appendix B).
-425
Error creating main Ligos processing thread.
-426
Error writing data to the Ligos video out-pin.
This is most likely a pin prob-
lem. It could be that the pro-
cessor can't handle all of the
requests at this bitrate
with
the dual-encode running.
-427
Ligos thread unable to access pointer to main-
process data and functions.
Timing error? Will probably
need to restart application.
-428
Error initializing one of the three Ligos out-pins.
-429
Invalid Ligos audio bitrate set in Registry. Must
be 64000, 96000, 112000, 128000, 160000,
192000, 224000, 256000, 320000, or 384000.
Check Ligos Registry to
ascertain that bitrate is
one of those listed.
Filter Manager Error/Status Codes (Continued)
Error Code
Meaning
Comments
Table C-1. Filter Manager Error/Status Codes (Continued)