MM147 - D4 Hot Melt Unit
Section 2 - Safety and Use
19
Hose Safety Information
DO NOT
DO
Do not
use bindings, wire
ties, or unapproved
fasteners around the
hoses.
Do
use approved wrapping
(P/N 775xx827), making
sure the wrapping is slightly
snug but not tight.
Do not
place hoses close
together.
Do
allow at least 2 inches
(5.1 cm) between hoses for
proper ventilation.
Do not
bend hoses
sharply.
Do not
allow kinks
or indentations in the
hoses.
Do
use a minimum bend
radius of 10 inches for a 20-
inch diameter coil hose.
Do not
use unapproved
hooks to hang hoses.
Do
not
wrap hoses over or
around objects.
Do
use a hose hanging kit
(P/N 781xx827).
Do not
use the “one
handed/one wrench”
technique to attach or
remove hoses.
Do not
wrench on any surface
other than the large
hexagon swivel nuts.
Do
use two hands and two
wrenches to tighten or
loosen connections on
hoses.
Do
wrench only on
large hexagon swivel nuts.
Do not
allow hoses to rub
against objects or to come
into contact with sharp
edges or points.
Do
wrap the hoses in
approved padding (P/N
795xx549) if the hoses must
be installed where they will
come into contact with
objects.
Do not
use worn,
damaged, or bent hoses.
Do
inspect all hoses
regularly for damage and/or
wear and replace damaged
or worn hoses immediately.
Содержание D4
Страница 1: ...D4 Hot Melt Unit Manual Number MM147 Revision Date 6 2018 ...
Страница 4: ......
Страница 10: ...Table of Contents MM147 D4 Hot Melt Unit 10 Module Status LED 170 Link Activity LED 170 ...
Страница 20: ...Section 2 Safety and Use MM147 D4 Hot Melt Unit 20 ...
Страница 22: ...Section 3 Basic Features MM147 D4 Hot Melt Unit 22 ...
Страница 35: ...MM147 D4 Hot Melt Unit Section 5 Setup 35 Section 5 Setup Control Panel ...
Страница 42: ...Section 5 Setup MM147 D4 Hot Melt Unit 42 Set Language Continued Next Page ...
Страница 43: ...MM147 D4 Hot Melt Unit Section 5 Setup 43 Set Language Continued ...
Страница 44: ...Section 5 Setup MM147 D4 Hot Melt Unit 44 Set Temperature Units ...
Страница 46: ...Section 5 Setup MM147 D4 Hot Melt Unit 46 Tank Temperature Hose Valve Temperature Continued Next Page ...
Страница 47: ...MM147 D4 Hot Melt Unit Section 5 Setup 47 Hose Valve Temperature Continued ...
Страница 54: ...Section 5 Setup MM147 D4 Hot Melt Unit 54 Beacon Alarm Setup Continued ...
Страница 55: ...MM147 D4 Hot Melt Unit Section 5 Setup 55 Beacon 2 ...
Страница 70: ...Section 5 Setup MM147 D4 Hot Melt Unit 70 Sequential Start Valve ...
Страница 100: ...Section 6 Operation MM147 D4 Hot Melt Unit 100 ...
Страница 106: ...Section 7 Maintenance MM147 D4 Hot Melt Unit 106 ...
Страница 110: ...Section 9 Specifications MM147 D4 Hot Melt Unit 110 Dimensions ...
Страница 112: ...Section 10 Part Number List MM147 D4 Hot Melt Unit 112 D4 Unit ...
Страница 113: ...MM147 D4 Hot Melt Unit Section 10 Part Number List 113 D4 Unit Continued ...
Страница 120: ...Section 10 Part Number List MM147 D4 Hot Melt Unit 120 D4 Base Unit 776xx392 ...
Страница 142: ...Section 11 Warranty MM147 D4 Hot Melt Unit 142 ...
Страница 144: ...Section 12 Service MM147 D4 Hot Melt Unit 144 ...
Страница 146: ...Appendix A Password Levels MM147 D4 Hot Melt Unit 146 Setting Level 0 as Default Continued ...
Страница 148: ...Appendix B Power Requirements MM147 D4 Hot Melt Unit 148 ...
Страница 150: ...Appendix C Instruction Sheets for Option Kits MM147 D4 Hot Melt Unit 150 ...
Страница 208: ...5 Valco Melton IS0343 Anybus Installation Installation Continued ...
Страница 245: ...Appendix E Communication Protocols Modus MM147 D4 Hot Melt Unit 162 ...