Section 5 - Setup
MM147 - D4 Hot Melt Unit
36
Control Panel, Continued
ITEM
NAME
DESCRIPTION
1
SYSTEM READY LED
ILLUMINATES GREEN WHEN THE SYSTEM REACHES READY
TEMPERATURE
2
WARNING LED
ILLUMINATES RED WHEN THE UNIT ENTERS AN ALARM CONDITION
3
SETBACK ON/OFF KEY
PUTS THE UNIT INTO AND OUT OF SETBACK MODE. THIS REDUCES
THE TEMPERATURE TO KEEP THE ADHESIVE SOFT BUT NOT
MOLTEN DURING DOWNTIME. YELLOW LED INDICATES THAT THE
SETBACK MODE IS INITIALIZED.
4
DISPLAY SCREEN
DISPLAYS THE MENU AND EVENT SCREENS
5
CLOCK ON/OFF KEY
TURNS THE CLOCK FUNCTION ON AND OFF. GREEN LED
INDICATES THE CLOCK IS ACTIVE.
6 STANDBY
KEY
PUTS THE UNIT IN AND OUT OF STANDBY. GREEN LED INDICATES
UNIT IS ON, ORANGE LED INDICATES UNIT IS IN STANDBY.
7
PLUS KEY
INCREASES THE VALUE OF THE SELECTED FIELD
8
RIGHT ARROW KEY
MOVES RIGHT THRU FIELDS ON THE SCREEN
9 OK
KEY
ENTERS OR EXITS A SCREEN WHERE A SELECTED FIELD CAN BE
EDITED.
10
MINUS KEY
DECREASES THE VALUE OF THE SELECTED FIELD
11
LEFT ARROW KEY
MOVES LEFT THRU FIELDS ON THE SCREEN
13
SETUP MENU KEY
DISPLAYS THE SETUP MENU SCREENS
14
TEMPERATURE MENU KEY
DISPLAYS THE TEMPERATURE GROUP SCREENS
15 GUN
LEDS
ILLUMINATES GREEN WHEN THE GUN ZONE IS HEATING AND RED
WHEN THE ZONE IS IN ALARM.
16 HOSE
LEDS
ILLUMINATES GREEN WHEN THE HOSE ZONE IS HEATING AND RED
WHEN THE ZONE IS IN ALARM.
17 TANK
LED
ILLUMINATES GREEN WHEN THE TANK ZONE IS HEATING AND RED
WHEN THE ZONE IS IN ALARM.
18
PUMP ON/OFF KEY
TURNS THE PUMP ON AND OFF. GREEN LED INDICATES PUMP IS
ACTIVE.
19
PUMP MENU KEY
DISPLAYS THE PUMP GROUP SCREENS
20
ABOVE OR BELOW
MINIMUM SPEED LEDs
APPLICABLE LIGHT ILLUMINATES WHEN SPEED IS ABOVE OR
BELOW MINIMUM SETTING.
21
LEVEL CONTROL LEDs
ALWAYS ON UNLESS LOW LEVEL OCCURS ON THE INTERNAL OR
EXTERNAL LEVEL CONTROL INPUTS.
Содержание D4
Страница 1: ...D4 Hot Melt Unit Manual Number MM147 Revision Date 6 2018 ...
Страница 4: ......
Страница 10: ...Table of Contents MM147 D4 Hot Melt Unit 10 Module Status LED 170 Link Activity LED 170 ...
Страница 20: ...Section 2 Safety and Use MM147 D4 Hot Melt Unit 20 ...
Страница 22: ...Section 3 Basic Features MM147 D4 Hot Melt Unit 22 ...
Страница 35: ...MM147 D4 Hot Melt Unit Section 5 Setup 35 Section 5 Setup Control Panel ...
Страница 42: ...Section 5 Setup MM147 D4 Hot Melt Unit 42 Set Language Continued Next Page ...
Страница 43: ...MM147 D4 Hot Melt Unit Section 5 Setup 43 Set Language Continued ...
Страница 44: ...Section 5 Setup MM147 D4 Hot Melt Unit 44 Set Temperature Units ...
Страница 46: ...Section 5 Setup MM147 D4 Hot Melt Unit 46 Tank Temperature Hose Valve Temperature Continued Next Page ...
Страница 47: ...MM147 D4 Hot Melt Unit Section 5 Setup 47 Hose Valve Temperature Continued ...
Страница 54: ...Section 5 Setup MM147 D4 Hot Melt Unit 54 Beacon Alarm Setup Continued ...
Страница 55: ...MM147 D4 Hot Melt Unit Section 5 Setup 55 Beacon 2 ...
Страница 70: ...Section 5 Setup MM147 D4 Hot Melt Unit 70 Sequential Start Valve ...
Страница 100: ...Section 6 Operation MM147 D4 Hot Melt Unit 100 ...
Страница 106: ...Section 7 Maintenance MM147 D4 Hot Melt Unit 106 ...
Страница 110: ...Section 9 Specifications MM147 D4 Hot Melt Unit 110 Dimensions ...
Страница 112: ...Section 10 Part Number List MM147 D4 Hot Melt Unit 112 D4 Unit ...
Страница 113: ...MM147 D4 Hot Melt Unit Section 10 Part Number List 113 D4 Unit Continued ...
Страница 120: ...Section 10 Part Number List MM147 D4 Hot Melt Unit 120 D4 Base Unit 776xx392 ...
Страница 142: ...Section 11 Warranty MM147 D4 Hot Melt Unit 142 ...
Страница 144: ...Section 12 Service MM147 D4 Hot Melt Unit 144 ...
Страница 146: ...Appendix A Password Levels MM147 D4 Hot Melt Unit 146 Setting Level 0 as Default Continued ...
Страница 148: ...Appendix B Power Requirements MM147 D4 Hot Melt Unit 148 ...
Страница 150: ...Appendix C Instruction Sheets for Option Kits MM147 D4 Hot Melt Unit 150 ...
Страница 208: ...5 Valco Melton IS0343 Anybus Installation Installation Continued ...
Страница 245: ...Appendix E Communication Protocols Modus MM147 D4 Hot Melt Unit 162 ...