MM147 - D4 Hot Melt Unit
Section 4 - Installation
29
Connecting the Hot Melt Hoses to the Applicators
WARNING!
If hand-held applicators are used, care should be taken to ensure safe operation. Heat
protective gloves should be worn. Hot melt is under high pressure at the nozzle tip of the
applicator. Failure to observe could result in personal injury (burns).
WARNING!
If hand-held applicators are used, operators should not work facing each other. Failure to
observe could result in personal injury (burns).
If fixed applicators are used, they should be protected from accidental contact by the
operator. Failure to observe could result in personal injury (burns).
CAUTION!
Hand-held applicators require a suitable hook for hanging while not in use. The hook must
support the weight of the applicator with the hose. Failure to observe could result in damage
to equipment.
Either hand-held or fixed applicators can be used with the unit.
To connect the fixed applicators, follow these steps:
1. Mount the applicator to the desired location on the parent machine.
Do not place applicators where the ambient temperature is low or
where there is a draft.
2. Connect the end of the hot melt hose (Figure 4-3) to the fluid inlet fitting on the applicator (Figure 4-4).
3. Connect the hot melt hose lead assembly’s female connector to the lead assembly on the applicator.
Figure 4-3. Hot Melt Hose
Figure 4-4. Applicator
Fluid inlet fitting
Lead assembly with female
connector (connects to lead
assembly on applicator)
End of glue hose that connects
to fluid fitting on applicator
Содержание D4
Страница 1: ...D4 Hot Melt Unit Manual Number MM147 Revision Date 6 2018 ...
Страница 4: ......
Страница 10: ...Table of Contents MM147 D4 Hot Melt Unit 10 Module Status LED 170 Link Activity LED 170 ...
Страница 20: ...Section 2 Safety and Use MM147 D4 Hot Melt Unit 20 ...
Страница 22: ...Section 3 Basic Features MM147 D4 Hot Melt Unit 22 ...
Страница 35: ...MM147 D4 Hot Melt Unit Section 5 Setup 35 Section 5 Setup Control Panel ...
Страница 42: ...Section 5 Setup MM147 D4 Hot Melt Unit 42 Set Language Continued Next Page ...
Страница 43: ...MM147 D4 Hot Melt Unit Section 5 Setup 43 Set Language Continued ...
Страница 44: ...Section 5 Setup MM147 D4 Hot Melt Unit 44 Set Temperature Units ...
Страница 46: ...Section 5 Setup MM147 D4 Hot Melt Unit 46 Tank Temperature Hose Valve Temperature Continued Next Page ...
Страница 47: ...MM147 D4 Hot Melt Unit Section 5 Setup 47 Hose Valve Temperature Continued ...
Страница 54: ...Section 5 Setup MM147 D4 Hot Melt Unit 54 Beacon Alarm Setup Continued ...
Страница 55: ...MM147 D4 Hot Melt Unit Section 5 Setup 55 Beacon 2 ...
Страница 70: ...Section 5 Setup MM147 D4 Hot Melt Unit 70 Sequential Start Valve ...
Страница 100: ...Section 6 Operation MM147 D4 Hot Melt Unit 100 ...
Страница 106: ...Section 7 Maintenance MM147 D4 Hot Melt Unit 106 ...
Страница 110: ...Section 9 Specifications MM147 D4 Hot Melt Unit 110 Dimensions ...
Страница 112: ...Section 10 Part Number List MM147 D4 Hot Melt Unit 112 D4 Unit ...
Страница 113: ...MM147 D4 Hot Melt Unit Section 10 Part Number List 113 D4 Unit Continued ...
Страница 120: ...Section 10 Part Number List MM147 D4 Hot Melt Unit 120 D4 Base Unit 776xx392 ...
Страница 142: ...Section 11 Warranty MM147 D4 Hot Melt Unit 142 ...
Страница 144: ...Section 12 Service MM147 D4 Hot Melt Unit 144 ...
Страница 146: ...Appendix A Password Levels MM147 D4 Hot Melt Unit 146 Setting Level 0 as Default Continued ...
Страница 148: ...Appendix B Power Requirements MM147 D4 Hot Melt Unit 148 ...
Страница 150: ...Appendix C Instruction Sheets for Option Kits MM147 D4 Hot Melt Unit 150 ...
Страница 208: ...5 Valco Melton IS0343 Anybus Installation Installation Continued ...
Страница 245: ...Appendix E Communication Protocols Modus MM147 D4 Hot Melt Unit 162 ...