Appendix
52
Installation and maintenance instructions ecoTEC plus 0020261188_00
#
Maintenance work
Interval
11
Cleaning the rainwater collector's draining circuit
Annually
36
12
Test that the product/heating installation and the domestic hot water gen-
eration (if required) are working correctly. If required, carry out a purging
process.
Annually
13
Check the product for gas, flue gas and water leaks
Annually
14
Checking and, if required, correcting the position of the frost protection
heating elements
Annually
15
Completing inspection and maintenance work
Required qualifications:
Authorised competent person
Annually
38
16
Checking the pre-charge pressure of the external expansion vessel
At least every 2 years
37
17
Cleaning the heat exchanger
At least every 2 years
35
18
Checking the burner
At least every 2 years
35
19
Checking the ignition electrode
At least every 2 years
36
20
Cleaning the filter in the dynamic air separation system
At least every 2 years
37
21
Cleaning the low loss header
At least every 2 years
G
Gas adjustment values
Set values, G20 natural gas
VC 406/5-5
(E-DE)
VC 476/5-5
(E-DE)
VC 636/5-5
(E-DE)
CO
₂
after 5 minutes in
full load mode with front
casing closed
9.2
±
1.0 vol.
%
9.2
±
1.0 vol.
%
9.2
±
1.0 vol.
%
CO
₂
after 5 minutes in
full load mode with front
casing removed
9.0
±
1.0 vol.
%
9.0
±
1.0 vol.
%
9.0
±
1.0 vol.
%
Set for Wobbe index W
₀
14.1 kW
⋅
h/m
³
14.1 kW
⋅
h/m
³
14.1 kW
⋅
h/m
³
O
₂
after 5 minutes in full
load mode with front cas-
ing closed
4.5
±
1.8 vol.
%
4.5
±
1.8 vol.
%
4.5
±
1.8 vol.
%
Set values, G25 natural gas
VC 406/5-5
(E-DE)
VC 406/5-5
(LL-DE)
VC 476/5-5
(E-DE)
VC 476/5-5
(LL-DE)
VC 636/5-5
(E-DE)
VC 636/5-5
(LL-DE)
CO
₂
after 5 minutes in
full load mode with front
casing closed
9.2
±
1.0 vol.
%
9.2
±
1.0 vol.
%
9.2
±
1.0 vol.
%
9.2
±
1.0 vol.
%
9.3
±
1.0 vol.
%
9.3
±
1.0 vol.
%
CO
₂
after 5 minutes in
full load mode with front
casing removed
9.0
±
1.0 vol.
%
9.0
±
1.0 vol.
%
9.0
±
1.0 vol.
%
9.0
±
1.0 vol.
%
9.1
±
1.0 vol.
%
9.1
±
1.0 vol.
%
Set for Wobbe index W
₀
14.1 kW
⋅
h/m
³
11.5 kW
⋅
h/m
³
14.1 kW
⋅
h/m
³
11.5 kW
⋅
h/m
³
14.1 kW
⋅
h/m
³
11.5 kW
⋅
h/m
³
O
₂
after 5 minutes in full
load mode with front cas-
ing closed
4.5
±
1.8 vol.
%
4.2
±
1.8 vol.
%
4.5
±
1.8 vol.
%
4.2
±
1.8 vol.
%
4.0
±
1.8 vol.
%
4.0
±
1.8 vol.
%
Set values, G31 liquefied petroleum gas
VC 406/5-5
(E-DE)
VC 406/5-5
(LL-DE)
VC 476/5-5
(E-DE)
VC 476/5-5
(LL-DE)
VC 636/5-5
(E-DE)
VC 636/5-5
(LL-DE)
CO
₂
after 5 minutes in
full load mode with front
casing closed
9.9
±
1.0 vol.
%
9.9
±
1.0 vol.
%
9.9
±
1.0 vol.
%
9.9
±
1.0 vol.
%
10.1
±
1.0 vol.
%
10.1
±
1.0 vol.
%
CO
₂
after 5 minutes in
full load mode with front
casing removed
9.7
±
1.0 vol.
%
9.7
±
1.0 vol.
%
9.7
±
1.0 vol.
%
9.7
±
1.0 vol.
%
9.9
±
1.0 vol.
%
9.9
±
1.0 vol.
%
Set for Wobbe index W
₀
21.3 kW
⋅
h/m
³
21.3 kW
⋅
h/m
³
21.3 kW
⋅
h/m
³
21.3 kW
⋅
h/m
³
21.3 kW
⋅
h/m
³
21.3 kW
⋅
h/m
³
O
₂
after 5 minutes in full
load mode with front cas-
ing closed
5.9
±
1.8 vol.
%
5.9
±
1.8 vol.
%
5.9
±
1.8 vol.
%
5.9
±
1.8 vol.
%
5.5
±
1.8 vol.
%
5.5
±
1.8 vol.
%