LAYOUT AND FUNCTION
21
(1)
Conductor rails connected in parallel
4.3.4
Fixed hangers/sliding hangers
All sections must be fastened at least twice, with the maximum hanger spacing of 1.2 m being observed. The
hanger brackets designed as sliding hangers allow three different types of fastening:
1) Installation in VAHLE support profile (clip fastening system)
2) Installation in C rail (screw fastening)
3) Installation on support brackets (screw fastening)
NOTICE!
The conductor system can slide in the hangers in case of longitudinal expansion. It is secured in the hanger
by an additional screw at fixed points. Here, a maximum distance of 6 m between two fixed points must be
maintained.
VM-SV10-8/63-100
0.445
8
781 156
VM-SV10-8/120-140
0.445
8
781 158
VM-SV10-9/63-100
0.460
9
781 159
VM-SV10-9/120-140
0.460
9
781 161
VM-SV10-9/200
(1)
0.460
9
781 162
VM-SV10-9/240-280
(1)
0.460
9
781 163
VM-SV10-10/63-100
0.475
10
781 164
VM-SV10-10/120-140
0.475
10
781 166
VM-SV10-10/200
(1)
0.475
10
781 167
VM-SV10-10/240-280
(1)
0.475
10
781 168
Type
Weight [kg]
Number of poles
ID no.
Содержание VKS10
Страница 86: ...MAINTENANCE 84 Connector cap moving along the rail before Connecting cap moving along the rail after ...
Страница 87: ...MAINTENANCE 85 Reversal points moving along the rail before Reversal points moving along the rail after ...
Страница 89: ...MAINTENANCE 87 Connecting caps mast assembly before Connecting caps mast assembly after ...
Страница 96: ...PROTECTIVE MEASURES 94 10 PROTECTIVE MEASURES 10 1 EU conformity declaration ...
Страница 99: ...CE Technical Documentation DQS certified in accordance DIN EN ISO 9001 2015 OHSAS 18001 2007 ...