LAYOUT AND FUNCTION
40
4.3.16
Single collector assembly KST
4.3.17
Single collector assembly KSTU
KST
Reversing operation
Connecting cable [m] 2
Stroke and lateral deflection [mm] ± 20
Contact pressure, approx. [N] 5
Type
Weight
[kg]
Current
[A]
Connecting cable
A [mm
2
] Ø
max.
[mm]
ID no.
Phase black
ID no.
PE yellow
SA-KST30PE-04A-2000
0.240
30
2.50
5
-
152 086
SA-KST30PH-04C-2000
0.240
30
2.50
5
152 085
-
SA-KST55PE-04D-2000
0.368
55
6.00
11
-
154 439
SA-KST55PH-04C-2000
0.368
55
6.00
11
154 438
-
SA-KST63PE-2000
0.394
63
10.00
9
-
156 792
SA-KST63PH-2000
0.394
63
10.00
9
156 791
-
KSTU
Reversing operation
for funnel operation and double line guides (multi
systems)
Connecting cable [m] 2
Stroke and lateral deflection [mm] ± 20
(± 10 mm to all sides in funnel area)
Contact pressure, approx. [N] 5
Type
Weight
[kg]
Current
[A]
Connecting cable
A [mm
2
] Ø
max.
[mm]
ID no.
Phase black
ID no.
PE yellow
SA-KSTU30/14PE-04A-2000 0.240
30
2.50
5
-
168 364
SA-KSTU30/14PH-04A-2000 0.240
30
2.50
5
168 363
-
SA-KSTU55/14PE-04D-2000 0.368
55
6.00
11
-
168 362
SA-KSTU55/14PH-04A-2000 0.368
55
6.00
11
168 361
-
SA-KSTU63/14PE-04D-2000 0.394
63
10.00
9
-
148 019
SA-KSTU63/14PH-04A-2000 0.394
63
10.00
9
148 018
-
Содержание VKS10
Страница 86: ...MAINTENANCE 84 Connector cap moving along the rail before Connecting cap moving along the rail after ...
Страница 87: ...MAINTENANCE 85 Reversal points moving along the rail before Reversal points moving along the rail after ...
Страница 89: ...MAINTENANCE 87 Connecting caps mast assembly before Connecting caps mast assembly after ...
Страница 96: ...PROTECTIVE MEASURES 94 10 PROTECTIVE MEASURES 10 1 EU conformity declaration ...
Страница 99: ...CE Technical Documentation DQS certified in accordance DIN EN ISO 9001 2015 OHSAS 18001 2007 ...