Table 128: The default values of parameters in the different applications
Index
Parameter
Default
Unit
ID
Description
A
B
C
D
E
F
3.2.1
Rem Control
Place
0
0
0
0
0
0
172
0 = I/O Control
3.2.2
Local/Remote
0
0
0
0
0
0
211
0 = Remote
3.2.6
I/O A Logic
2
2
2
2
2
2
300
2 = Forw-Back (edge)
3.2.7
I/O B Logic
2
2
2
2
2
2
363
2 = Forw-Back (edge)
3.3.1.5
I/O A Ref Sel
6
5
6
7
6
8
117
5 = AI2
6 = AI1 + AI2
7 = PID
8 = Motor Potentiometer
3.3.1.6
I/O B Ref Sel
4
4
4
4
4
4
131
4 = AI1
3.3.1.7
Keypad Ref Sel
2
2
2
2
2
2
121
2 = Keypad Reference
3.3.1.10
Fieldbus Ref
Sel
3
3
3
3
3
3
122
3 = Fieldbus Reference
3.3.2.1
Torque Ref Sel
0
0
0
0
4
0
641
0 = Not Used
4 = AI2
3.3.3.1
Preset Freq
Mode
-
-
0
0
0
0
182
0 = Binary Coded
3.3.3.3
Preset Freq 1
-
-
10.0 10.0 5.0
10.0
105
3.3.3.4
Preset Freq 2
-
-
15.0 -
-
-
Hz
106
3.3.3.5
Preset Freq 3
-
-
20.0 -
-
-
Hz
126
3.3.3.6
Preset Freq 4
-
-
25.0 -
-
-
Hz
127
3.3.3.7
Preset Freq 5
-
-
30.0 -
-
-
Hz
128
3.3.3.8
Preset Freq 6
-
-
40.0 -
-
-
Hz
129
3.3.3.9
Preset Freq 7
-
-
50.0 -
-
-
Hz
130
3.5.1.1
Ctrl Signal 1 A
100
100 100
100
100
100
403
100 = DigIN SlotA.1
VACON · 356
APPENDIX 1