ENGLISH
- 56 -
22.6 - TABLE OF PROGRAMMING PARAMETERS
PARAMETER
VALUE
SUBMENU DESCRIPTION
DEFAULT
CHAPTER
MEMO
MODE
Working mode
STAN
18
STAN
Standard
PRES
Dead man
S.PRE
Mixed
OROL
Timer
DIR
Gate direction (the direction you see from
the inside)
DX
DX
The gate opens rightwards
SX
The gate opens leftwards
P.APP
0-100%
Partial opening
50%
T.PRE
0.5”-10.0”
Pre-blinking time before opening
1.0”
13
NO
Function disabled
T.PCH
0.5”-10.0”
Pre-blinking time before closing
NO
13
NO
Pre-flashing during closing equal to T.PRE
POT
30-100%
Motor power
100
9
VEL
5-99HZ
Normal speed
50
9
VEL.R
5-99HZ
Slowed speed
25
9
SPUN
0-30%
Over voltage at start opening
0
9
ACCEL
0-6
Starting ramp
2
9
DECEL
0-6
Slowing ramp
2
9
FRENO
0-10
Brake intensity
4
9
RAL.A
0-50%
Slowed opening run
10%
9
RAL.C
0-50%
Slowed closing run
10%
9
VEL.M
5-99HZ
Speed in manual operation
30
19
ST.AP
Start during the opening phase
PAUS
16
PAUS
The gate stops and pauses
CHIU
The gate immediately starts closing
NO
The gate continues to open (the command is
ignored)
ST.CH
Start during the closing phase
STOP
16
STOP
The gate stops and the cycle is considered as
complete
APRE
The gate re-opens
ST.PA
Start during pause
CHIU
16
CHIU
The gate starts closing
NO
This command is ignored
PAUS
The pause time is reset