PARAMETER
VALUE
SUBMENU DESCRIPTION
DEFAULT
CHAPTER
MEMO
REL1
Relay 1 set up
LUCI
20
LUCI
Courtesy lights
NO
No function
CUST
Custom
20.7
ATTES
Relay contact closed while waiting for
commands
APERT
Relay contact closed during tests and the
opening
CHIUS
Relay contact closed when closing
PAUSA
Relay contact closed during the pause
ARRES
Relay contact closed when the gate is open
and automatic closing is disabled (parameter
CH.AU
)
TEST
12Vdc test
APRE
Open command
SERR
Lock
REL2
Relay 2 set up
NO
20
NO
No function
CUST
Custom
20.7
ATTES
Relay contact closed while waiting for
commands
APERT
Relay contact closed during tests and the
opening
CHIUS
Relay contact closed when closing
PAUSA
Relay contact closed during the pause
ARRES
Relay contact closed when the gate is open
and automatic closing is disabled (parameter
CH.AU
)
TEST
12Vdc test
CHIU
Close command
SERV
Service indicator
LUCI