ENGLISH
- 42 -
TOP BOARD
A1
Antenna shielding
A2
Antenna
S1
ING1 - configurable input to connect devices with
N.O. contact
ING1
parameter
DEFAULT =
START
(activates the cycle)
S2
ING2 - configurable input to connect devices with
N.O. contact
ING2
parameter
DEFAULT =
ST.PE
(partial opening)
S3
ING3 - configurable input to connect conventional
devices with N.O. contact
ING3
parameter
DEFAULT =
NO
(no function)
S4
Common (-)
S5
Photocell 1. N.C. contact
FOT1
parameter
DEFAULT =
NO
(no function)
S6
Photocell 2. N.C. contact
FOT2
parameter
DEFAULT =
CFCH
(enabled when closing and with
closed gate)
S7
Safety ribb. 1. N.C. contact
COS1
parameter
DEFAULT =
NO
(no function)
S8
Safety ribb. N.C. contact
COS2
parameter
DEFAULT =
NO
(no function)
S9
Common (-)
H1
Closing limit switch. N.C. contact (PRE-WIRED)
H2
Opening limit switch. N.C. contact (PRE-WIRED)
H3 - H4
NOT USED
H5
Common (-)
H6*
- Open gate warning light
- 24Vdc blinker
SPIA
parameter
DEFAULT =
W.L.
(open gate warning light)
H7
- Common open gate warning light
- 12Vdc common power supply
H8
12Vdc power supply
E1 / E2
24Vac accessory power supply
E3 / E4
Common accessories power supply
E5
Photocell TX power supply (24Vac) for Functional test
T1 - T2
Emergency STOP
7 - ELECTRIC CONNECTIONS
LOWER BOARD
MOTOR
U3-U2-U1
Motor (PRE-WIRED)
B2-B1
REL3 relay options (16A - 230V)
Parameter
REL3
DEFAULT =
NO
(no function)
OUTPUT
Z6-Z5
REL2 relay options (5A - 230V)
Parameter
REL2
DEFAULT =
NO
(no function)
OUTPUT
Z4-Z3
REL1 relay options (5A - 230V)
Parameter
REL1
DEFAULT =
LUCI
(courtesy lights)
OUTPUT
Z2-Z1
230V - 40W blinker
N - L
230V - 50Hz power supply network
W
G1 - G2
Ground terminal for connection of the ground
system and the motor
OTHER
F1
T320mA. Power supply fuse
F2
F10A. Motor inverter fuse
ADI
ADI interface
RECEIVER
MR receiving modules
OVERLOAD
It indicates a 24Vac power overload of
accessories
POWER
LOGIC
It indicates that the control unit is powered
POWER
MOTOR
It indicates the inverter driving the motor is
powered
OK
GREEEN LED
Flashes when the inverter driving the motor is in
stand-by
Turned on and fixed when the motor is running
ATTENTION
YELLOW LED
Flashes when the power supply of the inverter
driving the motor is charging
Turned on and fixed when the emergency STOP
is on
ERROR
RED LED
Turned on and fixed when a fault of the encoder
is detected