D292105.7b.fm
Configure HMI Settings
Chapter 4: Setup
4- 19
8.
SET PICK HEIGHT.
a.
Open the TM-402 enclosure doors to access the pick head.
b.
Use a 2.5mm hex wrench to hold the
Actuator Adjustment Screw
in place from
the bottom, while loosening the
Jam Nut
on top of the
Actuator Adjustment Screw
with
an 8mm open ended wrench
.
Raise
the
Nozzle
until it is at a safe height so it
will not collide with the current part when
extended.
c.
Tighten the
Jam Nut
.
d.
Press the
Pick Extend
button
.
e.
Loosen the
Jam Nut
on top of the
Actuator Adjustment Screw
again, then
lower the
Nozzle
until it is barely touching the part in the
Pick Location
.
Note
: For all
Nozzle Tips
except the
Convum Tips
, the pick position should be set
just above the surface of the part with a very small clearance between the nozzle
and the part. Because the
Convum Nozzle Tips
are flexible, it is all right if the tip is
programmed to touch the part when picking.
f.
Tighten the
Jam Nut
.
g.
Press
Pick Retract
to retract the
Nozzle
to a safe height.
h.
Press the right
Arrow
to move to the next
Job Wizard
screen.
Step 6:
Setup HMI
PICK
HEAD
Содержание TM-402
Страница 4: ......
Страница 72: ...3 30 TM 403 User s Guide Run Tab D292105 6a fm...
Страница 156: ...6 12 TM 403 User s Guide Preparing to Run a Pre programmed Job D292105 8b fm...
Страница 197: ...Appendix A Sensors Contents Keyence FS N11CVP FS N12CP Sensor Amplifiers A 2 SMC ZSE30 Vacuum Sensor A 4...
Страница 202: ...Appendix A Sensors A 6 SMC ZSE30 Vacuum Sensor D291842 11 fm...
Страница 294: ......
Страница 298: ...751 Summit Avenue Mankato MN 56001 507 387 2039 FAX 507 387 2257 www vtekusa com Email info vtekusa com...