D292105.10a.fm
General Maintenance Tasks
Chapter 8: Maintenance
8- 5
Pick Head Maintenance
Nozzle Tip
Inspect the nozzle tip
daily
for excessive wear or damage. Remove and replace as necessary.
See
Chapter 4: Machine Setup
for instructions on changing the nozzle tip.
Vacuum Levels
.
Check Vacuum levels
weekly
. This recorded information on high/
low vacuum levels is useful on a week to week basis and can indi-
cate pneumatic problems such as loose fittings or seal problems.
1.
Turn on the vacuum generator from the HMI.
2.
Observe and record vacuum level for the nozzle with no part
present.
3.
Cover the nozzle (with part or some object) and record vac-
uum levels.
4.
Compare the current vacuum levels with those previously recorded.
A partially blocked
nozzle or restricted filter in the nozzle assembly is indicated by a smaller vacuum swing.
5.
Remove and replace the nozzle vacuum filter if there are high vacuum levels without part
or poor pickup.
Replace the Vacuum Filter
If parts are not picking consistently or if the
Nozzle
Vacuum
Sensor
indicates there is a part on the
Nozzle
(values appear
green) without a part on the nozzle, this is an indicator that the
Vacuum Filter
needs to be cleaned or replaced. Typically the
Vacuum Filter
will require attention after 200-300 hours of
operation.
The
Vacuum Filter
is located on top of the
Pick Head Assem-
bly.
1.
Open the front door and manually move the pick head
all the way to the front for easy access.
Содержание TM-402
Страница 4: ......
Страница 72: ...3 30 TM 403 User s Guide Run Tab D292105 6a fm...
Страница 156: ...6 12 TM 403 User s Guide Preparing to Run a Pre programmed Job D292105 8b fm...
Страница 197: ...Appendix A Sensors Contents Keyence FS N11CVP FS N12CP Sensor Amplifiers A 2 SMC ZSE30 Vacuum Sensor A 4...
Страница 202: ...Appendix A Sensors A 6 SMC ZSE30 Vacuum Sensor D291842 11 fm...
Страница 294: ......
Страница 298: ...751 Summit Avenue Mankato MN 56001 507 387 2039 FAX 507 387 2257 www vtekusa com Email info vtekusa com...