D292105.9b.fm
System Alarm Messages
Chapter 7: Troubleshooting
7-7
Note:
There are a variety of error conditions which could cause the machine to stop. See
the
Error Message Table
at the end of this section for an explanation of the various error
messages and their suggested solutions.
An illustration and description of each
System Alarm Message
follows.
Part Not Picked System Alarm
If the nozzle is unable to pick a part from the Bowl Feeder, the
Part Not Picked
system alarm will
be activated. When this happens, operation stops, a beep sounds, and a warning appears on the
HMI.
To clear the
Unable to Pick
Alarm,
ensure there are parts in the bowl and it is feeding properly
with no jams in the feeding track. If that does not resolve the problem, ensure the
Pick Height
is
not set too high. Finally, verify the
Vibratory
is
Enabled
.
When the
Bowl Feeder
is ready for operation, press
CONTINUE
to clear the alarm and resume
operation.