![Utilimaster REACH Скачать руководство пользователя страница 77](http://html.mh-extra.com/html/utilimaster/reach/reach_service-manual_1065305077.webp)
Utilimaster Corporation attempts to provide
information that is accurate, complete, and
useful. All information contained in this
manual is based on the latest product infor-
mation available at the time of publication.
However, because of the Utilimaster policy
of continual product improvement, Utilimas-
ter reserves the right to amend the informa-
tion in this document at any time without
prior notice.
This material is confidential and the prop
-
erty of Utilimaster. It is shared with your
company for the sole purpose of helping you
with the operation of the described equip-
ment.
Utilimaster makes no warranty of any kind
with regard to this material, including, but
not limited to, the implied warranties of
merchantability and fitness for a particular
purpose. Utilimaster shall not be liable for
errors contained herein or for incidental or
consequential damages in connection with
the furnishing, performance, or use of this
material.
Utilimaster expressly disclaims all respon-
sibility and liability for the installation, use,
performance, maintenance, and support of
third-party products. Customers are advised
to make their independent evaluation of such
products.
No part of this document may be photo-
copied, reproduced, or translated to another
language without the prior written consent
of Utilimaster.
Utilimaster Corporation attempts to provide
information that is accurate, complete, and
77
For Assistance Call: 800-237-7806
Parts On-line:
https://parts.utilimaster.com
Reach—Body Service Manual
Fax: 574-862-7637
5. Release the cable drum from the shaft by loosening the two set screws on the cable drum and
remove cable.
6. Remove the cotter and anchor pins to remove cable from bottom door panel.
Installation
NOTE: The cable must be wound from the outermost groove toward the inside of the drum.
1. Secure the cable end to the anchor bracket with an anchor pin.
2. Secure anchor pin with a cotter pin.
3. Bring cable ends to top of door and tape to the inside of vehicle.
4. With door closed, bring cable up between drum and header and hook cable end in the slot in
outer groove of cable drum.
5.
Push cable drum tight against the bearing, and starting in first groove, wind cable on drum.
Ensure it properly tracks in each groove of drum.
6. Ensure cable drum is tight against the bearing and tighten setscrews.
7. Adjust spring.
Cable drum
Cotter and anchor pins
CAUTION: Ensure the drums are against the counterbalance shaft bearings, the setscrews are
properly tightened, and the cables have equal tension.
Rotating the counterbalance assembly too far may cause the cables to jump off the cable drum.