Samp. Ref. Diff.
55
Next, a results screen will show the sampler’s flow rate, the reference
flowmeter’s flow rate and the difference. Press
ENTER
to continue.
21.95 22.00 -0.05
ENTER=Next
Save audit results
to memory card?
The next screen prompts you to save audit results to memory card. Press
YES
to save these results, press
NO
to cancel.
YES=Save NO=Cancel
Audit results saved
to memory card.
When audit results have been saved, press
ENTER
to return to the Audit
Menu.
8.4 Temperature
Audit
ENTER=Next
Pressing
←
F3
on the Audit Menu brings you to the Temperature
Audit Temperature
Temperature(C)= 25.4
Audit screen. You are prompted to enter the Reference Temperature.
Pressing the
↑
F1
key will toggle between positive and negative values
whereas pressing
↓
F2
will toggle Celsius/Fahrenheit. Press
ENTER
to
accept the entered value.
F1:+/- F2:C/F
Ref. Temp(C):?
C/F Samp. Ref. Diff.
C 25.4 25.0 0.4
The following screen will display the results for the sampler’s temperature,
reference temperature and the difference, in Celsius and Fahrenheit.
Press
ENTER
to proceed.
F 77.7 77.0 0.7
ENTER=Next
Save audit results
to memory card?
The next screen prompts you to save the audit results. Press
YES
to save
the results or
NO
to cancel them.
YES=Save NO=Cancel
Audit results saved
to memory card.
The next screen will confirm that the results have been saved to the
memory card. Press
ENTER
to return to the Audit Menu.
ENTER=Next
8.5 Barometric Pressure Audit
Audit BP
You are prompted to enter reference Barometric pressure in mmHg.
Pressing
↑
F1
will toggle positive/negative values, and the
BKSP
key can
be used to make any corrections.
BP (mmHg)= 643.9
Ref. BP(mmHg):?