5. Do not rigidly anchor
Uponor AquaPEX piping
with supports. Allow
enough piping for freedom
of movement to expand
and contract.
6. Allow adequate clearance
between PEX piping and
the structure (bored holes
or sleeves) to allow freedom
of movement for thermal
expansion and contraction.
Piping support spacing
Anchor Uponor AquaPEX piping
securely enough to support
the piping, yet relaxed enough
to allow the piping to expand
and contract.
1. Along horizontal runs,
install supports every
32". If horizontal runs are
continuously supported,
place the piping supports at
6' intervals (see Figure 6-3).
2. Along vertical runs, install
supports every 4' to 5' at
each floor and at a mid-story
guide (see Figure 6-4).
Note: When piping is installed
in an area that will be left
exposed or unfinished, metal
piping supports are required
every 24". (see Figure 6-2)
32"
Figure 6-3: Horizontal runs
Figure 6-4: Vertical runs
Piping
supports
Figure 6-2: Metal piping supports
26 l Uponor AquaSAFE System Installation Guide