background image

-12-

UNIT PREPARATION

After carefully unpacking and reading the instructions for installing your stove, you will need to perform the 

following steps:

•  Attach the included spring handle to the door handle by screwing it on in a respective location.

• 

Attach the electrical cord to the back of the stove first; then plug it into a 110-volt outlet (an outlet surge 

protector is highly recommended).

PERFORMING AN INITIAL TEST

This test is used at the factory where the stoves are assembled to test the functionality of the control and the stove 

before the unit is shipped. To perform this test, press and hold the OFF and AUGER DELAY buttons simultaneously 

for 3 seconds. To advance through the test, press any key unless otherwise noted in the test step.

1. 

Exhaust Fan Output Test – The display will show “drft”. The exhaust fan is turned on full then reduced to a level 

just above the typical minimum pressure switch setting. The ON LED indicates whether the pressure sensor 

is detected. If the pressure switch is not detected, the fan ramps to full on for two seconds then returns to 

the previously established level if the pressure switch closes. If the Draft Fan Fuse is not blown and the fuse 

detection circuit is functioning, the Draft Fan LED will be lit and the other three top row LEDs will be off.

2.  Room Fan Output Test - The display will show “rfan”. The room fan is turned on full. If the Room Fan Fuse is not 

blown and the fuse detection circuit is functioning, the Room Fan LED will be lit and the other three top row 

LEDs will be off.

3. 

Ignitor Output Test - The display will show “ignt”. The ignitor motor is turned on full. If the Ignitor (AUX) Fuse is 

not blown and the fuse detection circuit is functioning, the Aux LED will be lit and the other three top row 

LEDs will be off.

4.  Auger Output Test - The display will show “augr”. The auger motor is turned on full. If the Auger Fuse is not 

blown and the fuse detection circuit is functioning, the Heat Range LED will be lit and the other three top 

row LEDs will be off.

5.  Hopper Switch Test – The display will show “hppr”. The “ON” LED is lit. If the hopper switch is open (lid is open), 

the “HEAT RANGE” LED will turn on. If the lid is closed, the “HEAT RANGE” LED will be off.

6. 

Thermostat Input Test – The display will show “stat”. If the thermostat input is closed, the ON LED will turn on, 

otherwise it will be off.

7.  Flue gas Thermistor Test – The display will show the flue gas temperature in degrees F.

8.  AC Frequency Test - Displays the measured AC Frequency in hertz (59-60) followed by the letter ‘H’.

9.  Watchdog Reset – The watchdog timer is tested to ensure that the board can be reset. The message “BYE” 

is displayed until the watchdog resets the board.

PERFORMING A “DRY RUN”

Perform a “dry run” on your stove prior to making the exhaust/inlet connections and starting your stove for the 

first time.

1. 

Check that there is no fuel or ANY foreign material in the hopper or burn-pot.

2. 

Check that the viewing door and hopper lid is securely closed.

3. 

Press the “ON” button on the control panel. Verify that the ON LED is lit (blinking) and the display shows HR-1. 

Also the LED above the HEAT RANGE and the AUTO MODE indicator should be lit. If any other LED’s are lit or 

flashing, consult the “Display Indicators” in this manual.

4.  You should hear the exhaust (draft) fan running immediately and the auger should begin turning continuously 

for 1 minute.

5.  The auto fuel ignitor (located inside the backwall of the burnpot) should begin to glow red/orange after 3 

minutes.

6.  The Room Fan will not operate at this time since the unit must reach a factory preset temperature.

Do not open the viewing door, the auto-start igniter will get very hot during this test. The stove will automatically 

shut down after approximately 23 minutes.

• 

DO NOT USE CHEMICALS OR FLUIDS TO START THE FIRE - Never use gasoline, gasoline-type lantern fuel, 

kerosene, charcoal lighter fluid, or similar liquids to start or “freshen up” a fire in this stove. Keep all such 

liquids well away from the stove while it is in use.

• 

HOT WHILE IN OPERATION. KEEP CHILDREN, CLOTHING AND FURNITURE AWAY. CONTACT MAY CAUSE SKINS 

BURNS.

• 

DO NOT USE GRATES OR ELEVATE THE FIRE. BURN POT HAS TO BE IN ITS INTENDED LOCATION. 

Operation

Содержание KP130

Страница 1: ...he appliance Keep viewing and ash removal doors tightly closed during operation Replace glass with 5mm ceramic glass ONLY IMPORTANT When the hopper lid is open the auger will stop Close the hopper lid...

Страница 2: ......

Страница 3: ...R FUTURE REFERENCE Please read this entire manual before installation and use of this appliance Failure to follow these instructions could result in property damage bodily injury or even death Contact...

Страница 4: ...ced on a non combustible surface or on the ground well away from all combustible materials pending final disposal The exhaust system should be checked monthly during the burning season for any build u...

Страница 5: ...Environmental Protection Agency s crib wood emission limits for wood heaters sold after May 15 2020 Under specific EPA test conditions burning wood pellet fuel this heater has been shown to deliver he...

Страница 6: ...an NFI certified specialist IMPROPER INSTALLATION The manufacturer will not be held responsible for damage caused by the malfunction of a stove due to improper venting or installation Call 800 750 272...

Страница 7: ...m CORNER D Adjacent wall to unit 8 00 203mm ALCOVE E Alcove depth 36 00 914mm 5500 M only F Alcove height 60 00 520mm CLEARANCES Your pellet stove has been tested and listed for installation in reside...

Страница 8: ...the stove use a 3 inch to 4 inch adapter for 4 inch pipe Connection at back of stove must be sealed using Hi Temp RTV Use 4 inch vent if the vent height is over 12 feet or if the installation is over...

Страница 9: ...ction of pipe should be added with a horizontal cap which would complete the installation see FIGURE 7 A support bracket should be placed just below the termination cap or one every 4ft 1 22m to make...

Страница 10: ...ection to the heater SPECIAL MOBILE HOME REQUIREMENTS WARNING Do not install in a sleeping room CAUTION The structural integrity of the mobile home floor wall and ceiling roof must be maintained A wor...

Страница 11: ...a forced draft pressure is required for the combustion process inside your stove it is extremely important that the exhaust system be properly installed and maintained And that when operating your st...

Страница 12: ...at will not properly control the unit When adjusting the Draft Fan setting try only 1 setting above or below the heat setting It is better to leave the stove in the automatic mode ROOM FAN The room fa...

Страница 13: ...the preselected desired heat range setting 1 to 5 and the minimum heat range setting of 1 The T Stat will not turn the stove on and off When the desired room temperature has been reached and the T Sta...

Страница 14: ...w LEDs will be off 5 Hopper Switch Test The display will show hppr The ON LED is lit If the hopper switch is open lid is open the HEAT RANGE LED will turn on If the lid is closed the HEAT RANGE LED wi...

Страница 15: ...the heat exchanger in the stove reaches the factory preset temperature Attempts to achieve heat output rates that exceed heater design specifications can result in permanent damage to the heater First...

Страница 16: ...ck panel or opening the exhaust system for any inspection cleaning or maintenance work Never perform any inspections cleaning or maintenance on a hot stove Do not operate stove with broken glass leaka...

Страница 17: ...We recommend using a high quality glass cleaner Should a build up of creosote or carbon accumulate you may wish to use 000 steel wool and water to clean the glass DO NOT use abrasive cleaners DO NOT p...

Страница 18: ...re that the viewing door is closed and sealed properly If not adjust door catch and or replace door gaskets Check that all outside connections are clear of any obstructions Check the exhaust system cl...

Страница 19: ...tor This indicates that the stove is in normal operation and is running in the automatic mode However either the draft fan or room fan setting is manually configured Flashing Draft Fan Setting Indicat...

Страница 20: ...18 GRAY BLACK Wiring Diagram CORRECT WRONG Ensure the wires are connected to the bottom two prongs of the hopper switch as shown...

Страница 21: ...ght 1 12 69787 Hopper Assembly 1 13 80491 MIcroswitch 1 14 83541 4 40 Bolt 2 15 893039 Remote Sensor Bracket 1 16 25480MB Access Panel 1 17 80461 Power Supply Cord 1 18 80462 Receptacle 3 Prong 1 19 8...

Страница 22: ...20 9 3 2 1 5 6 4 7 8 10 Parts Diagram 47 46 48 49 50...

Страница 23: ...07 Date _____________________ Engineer Name ________________________________ License No ____________________________________ Company _____________________________________ Telephone No _______________...

Страница 24: ...s pi ces d tach es Gardez ce manuel dans un lieu s r pour toute consultation ult rieure Lorsque vous nous crivez donnez toujours le num ro de mod le complet qui se trouve sur la plaque signal tique fi...

Страница 25: ...____________________________ Service de 07 Date _____________________ Nom de l ing nieur ____________________________ N de licence _________________________________ Compagnie _________________________...

Страница 26: ...e Droit 1 12 69787 Assembl e Hopper 1 13 80491 Micro Interrupteur 1 14 83541 4 40 Bolt 2 15 893039 Support de capteur distance 1 16 25480MB Panneau D acc s 1 17 80461 Cordon D alimentation 1 18 80462...

Страница 27: ...20 Sch ma des pi ces 9 3 2 1 5 6 4 7 8 10 47 46 48 49 50...

Страница 28: ...SOSTAT MARRON MARRON NOIR BLANC ROUGE BLEU ORANGE PRISE MOLEX AU CIRCUIT IMPRIM PCB PRINCIPAL NOIR NOIR NOIR BLANC BLANC SOUFFLANTE DE DISTRIBUTION VENTILATEUR D VACUATION THERMISTOR Sch ma de c blage...

Страница 29: ...eux fois par seconde Cela indique que le po le fonctionne normalement et qu une condition de temp rature excessive existe provoquant l arr t du combustible Indicateur de r glage du niveau de chaleur H...

Страница 30: ...e V rifiez que le raccordement du pressostat au foyer ne contienne aucune cendre ni obstruction Le syst me vis sans fin est bloqu ou il y a une vo te de combustible dans la tr mie qui emp che le combu...

Страница 31: ...le et d paisseur correctes doivent tre utilis es NE substituez PAS le verre avec des mat riaux alternatifs Contactez votre revendeur autoris pour obtenir ce verre R installez le nouveau verre en le fi...

Страница 32: ...fi peut effectuer ces travaux Il est aussi recommand qu avant chaque saison de chauffage le syst me complet soit inspect nettoy et si n cessaire r par par un professionnel Pour nettoyer la chemin e d...

Страница 33: ...sur le bouton OFF arr t et ensuite de nouveau sur le bouton ON marche pour commencer une nouvelle s quence de mise en route 2 Si le po le a refroidi il se r initialisera l tat OFF arr t ce moment l vo...

Страница 34: ...de l eau sal e 11 Bois non s ch ou 12 Produits du papier carton contreplaqu ou panneau de particules L interdiction de br lage de ces mat riaux n interdit pas l utilisation d allume feu compos s de pa...

Страница 35: ...fin se met en marche plein r gime Si le fusible de la vis sans fin n a pas saut et que le circuit de d tection fusible fonctionne le voyant DEL Heat Range du degr de chaleur sera allum et les trois au...

Страница 36: ...justez le r glage du ventilateur de tirage essayez seulement 1 r glage au dessus ou en dessous du r glage de chaleur Il est pr f rable de laisser le po le en mode automatique VENTILATEUR DE LA PI CE L...

Страница 37: ...rage forc e est n cessaire au processus de combustion l int rieur de votre po le il est extr mement important que le syst me d vacuation soit install correctement et maintenu Et que lors du fonctionne...

Страница 38: ...ionn de la plage de chaleur d sir e 1 5 et le r glage de la plage de chaleur minimale de 1 Le T Stat n allumera ni ne teindra le po le Lorsque la temp rature ambiante souhait e est atteinte et que le...

Страница 39: ...nag e Apr s le d m nagement tous les vents doivent tre r install s et fix s fermement L air ext rieur est obligatoire pour l installation d une maison mobile Consultez votre revendeur lors de l achat...

Страница 40: ...rd en T de regard devra tre plac sur le tuyau avec une sortie 90 degr s hors de la maison ce point une partie de tuyau de 3 pieds 0 91m minimum devra tre ajout e avec un couvercle horizontal qui devra...

Страница 41: ...e doit tre scell en utilisant un produit vulcanis RTV pour temp ratures lev es Utilisez une ventilation de 4 pouces si la hauteur de ventilation est sup rieure 12 pieds ou si l installation se trouve...

Страница 42: ...re minimum plus grand afin d obtenir un acc s commode au panneau de contr le FIGURE 3 D GAGEMENTS DE LA PAROI LAT RALE INSTALLATION EN PARALL LE FIGURE 4 D GAGEMENTS DE LA PAROI LAT RALE INSTALLATION...

Страница 43: ...cialiste certifi NFI NE CONNECTEZ PAS CETTE UNIT UN CONDUIT OU CIRCUIT DE DISTRIBUTION D AIR INSTALLATION INCORRECTE Le fabricant ne sera pas tenu responsable des dommages caus s par un dysfonctionnem...

Страница 44: ...vos pellets dans un endroit sec NE stockez PAS le carburant dans les d gagements d installation de l appareil ou dans l espace requis pour faire le plein et enlever les cendres Cela pourrait provoque...

Страница 45: ...oivent tre jet es dans un conteneur m tallique avec un couvercle d ajustement serr Le conteneur ferm dans lequel se trouvent les cendres devra tre plac sur une surface non combustible ou sur le sol bi...

Страница 46: ...reil n est pas destin tre utilis en tant que principale source de chaleur U S Environmental Protection Agency Certifi aux normes d missions de 2020 particules CONSERVEZ CES INSTRUCTIONS CE MANUEL VOUS...

Отзывы: