CAUTION

• 

Important  operating 

and  maintenance 

instructions included.

•  Leave this manual with 

party  responsible  for 

use and operation.

•  Read,  understand  and 

follow these instructions 

for safe installation and 

operation.

DO NOT

DISCARD

 WARNING

If the information in these instruc-

tions is not followed exactly, a 

fire may result causing property 

damage, personal injury, or death.

 

•  Do not store or use gasoline or other flam

-

mable vapors and liquids in the vicinity of 

this or any other appliance.

•  Do not overfire - If heater or chimney con

-

nector glows, you are overfiring. Overfiring 

will void your warranty.

•  Comply with all minimum clearances to 

combustibles as specified.  Failure to 

comply may cause house fire.

Fire Risk.

WARNING

For use with solid wood fuel only.

Other fuels may overfire and generate 

poisonous gases (i.e. carbon monoxide).

Installation and service of this appliance should 

be performed by qualified personnel.  Hearth & 

Home Technologies recommends NFI certified 

professionals, or technicians supervised by an 

NFI certified professional.

WARNING

Hot glass will cause burns.

•  Do not touch glass until it is cooled

•  NEVER allow children to touch glass

•  Keep children away

•  CAREFULLY SUPERVISE children in same room 

as fireplace.

•  Alert  children  and  adults  to  hazards  of  high 

temperatures.

High  temperatures  may  ignite  clothing  or  other 

flammable materials.

•  Keep  clothing,  furniture,  draperies  and  other 

flammable materials away.

HOT SURFACES!

Glass and other surfaces are 

hot during operation AND 

cool down.

To obtain a French translation of this manual, please 

contact your dealer or visit www.quadrafire.com

Pour obtenir une traduction française de ce manuel, 

s’il vous plaît contacter votre revendeur ou visitez 

www.quadrafire.com

NOTE

3100 WOOD STOVE SERIES

Automatic Combustion Control (ACC)

Owner’s Manual

Installation and Operation

Models: 

31M-ACC-MBK

31ST-ACC

Millennium Model

Step Top Uni-Body Model

(Pedestal Model Shown)

O-T  L

Tested and 

Listed by

Portland

Oregon USA

OMNI-Test Laboratories, Inc.

C

US

Содержание 31M-ACC-MBK

Страница 1: ...is appliance should be performed by qualified personnel Hearth Home Technologies recommends NFI certified professionals or technicians supervised by an NFI certified professional WARNING Hot glass wil...

Страница 2: ...talling unit SERIAL NO NUM RO DE S RIE A B C D E F E F G H G A B C D R 16 from glass 8 USA Fuel loading door Millennium Step Top 31 5 8 Min Millennium Step Top 39 5 8 minimum 7033 278 CANADA 203mm 8 2...

Страница 3: ...ion 8 Operating Instructions A Over Firing Your Appliance 25 B Wood Selection Storage 25 C Burning Process 25 26 D Automatic Combustion Control ACC 26 E Air Controls 26 27 F Burn Rates Operating Effic...

Страница 4: ...et Max Wood Length 18 inches Fuel Cord Wood Shipping Weight 325 lbs Model 3100 Millennium Step Top Uni Body ACC Laboratory OMNI Test Laboratories Inc Report No Date 061 S 66 6 Type Listed Room Heater...

Страница 5: ...appliance and close to the sleeping areas Follow the smoke detector manufacturer s placement and installation instructions and be sure to maintain regularly 2 A conveniently located Class A fire exti...

Страница 6: ...nclude Exhaust fans kitchen bath etc Range hoods Combustion air requirements for furnaces water heaters and other combustion appliances Clothes dryers Location of return air vents to furnace or air co...

Страница 7: ...e after one hour of operation at each burn setting NOTE These are guidelines only and may vary somewhat for individual installations F Tools And Supplies Needed Before beginning the installation be su...

Страница 8: ...rmination Cap Outside Air Rear Vent Spark Arrestor Cap Floor Protector Chimney Connector Ceiling Support Listed Chimney Listed Termination Cap Storm Collar Flashing Figure 8 3 Interior Prefabricated C...

Страница 9: ...mm 11 1 2 in 292mm 20 3 4 in 527mm C L 4 1 2 in 108mm Outside Air Connection C L A Appliance Dimensions Figure 9 1 Front View Figure 9 2 Side View NOTE Flue Collar size is 6 inch 152mm diameter ID 14...

Страница 10: ...p Top Leg Model 23 7 8 in 606mm 33 1 8 in 841mm 15 1 16 in 383mm 19 1 16 in 484mm 10 15 16 in 278mm 14 15 16 in 379mm 3 11 16 in 94mm 21 1 8 in 537mm 10 3 8 in 264mm 6 11 16 in 170mm 3 1 2 in 89mm C L...

Страница 11: ...tove Through Backwall SINGLE WALL PIPE Flat Top Model 12 305 8 5 216 22 559 13 330 8 203 17 432 48 1220 12 305 Step Top Model 10 254 6 152 20 5 521 11 279 5 5 140 14 5 368 48 1220 12 305 DOUBLE WALL P...

Страница 12: ...open ing in the face of the appliance See exception 16 in from glass 8 in Fuel loading door 4 7 8 in 3 1 8 in 31 5 8 in minimum 39 5 8 in minimum Must extend 2 in 51mm beyond each side of pipe shaded...

Страница 13: ...hick metal clad millboard or equivalent a minimum of 16 inches 406mm in front of glass and 8 inches 203mm to both sides of the fuel loading door Open the door and measure 8 inches 203mm from the side...

Страница 14: ...htly sealed doors and windows an outside air source is needed An optional Outside Air Kit is available Flex Line Wire Tie Wire Tie Flex Adapter Termination Cap For Floor Installa tions Remove Circular...

Страница 15: ...der the bottom left rear corner as shown in Figure 15 1 See page 30 for detailed operating instructions for the blower and snap disc Shock Risk Do NOT remove grounding prong from plug Plug directly in...

Страница 16: ...eel black or 26 gauge blued steel or an approved air insulated double wall venting pipe Thimble A manufactured or site constructed device installed in combustible walls through which the chimney conne...

Страница 17: ...ng lumber to fit into wall opening Inside opening of frame should be no less than 14 inch x 14 inch 356mm x 356mm Figure 17 1 4 Attach the wall spacer to the chimney side of the frame 5 Nail the frame...

Страница 18: ...rs must conform to each other to ensure a proper fit and seal Flue Gas Direction Crimped End Toward Stove Secure pipe sections with a minimum of 3 screws Figure 18 2 Chimney Connector Stove Pipe WARNI...

Страница 19: ...oof within 10 feet 305cm Must be located away from trees or other struc tures These are safety requirements and are not meant to assure proper flue draft Figure 19 1 E 2 10 3 Rule Figure 19 2 NOTE Chi...

Страница 20: ...nector UL103 HT chimney and terminal cap with spark arrestor Never use a single wall connector stove pipe in a mobile home installation Use only double wall connector pipe Dura Vent DVL Selkirk metalb...

Страница 21: ...ncluded If not needed discard Tools Required Phillips head screwdriver 7 16 socket wrench 3 32 and 5 36 Allen wrench Begin installing the ARS System 1 Remove 2 front bricks as shown in Figure 21 1 2 L...

Страница 22: ...refully stand stove up and place in desired location 5 Slip wooden decorative strips onto pedestal edges Finishing the ARS Installation 1 Re install the ARS channel that was removed in Step 3 on page...

Страница 23: ...rews are located in the component pack Leave the bottom 2 screws loose so you can slide the ash pan assembly bottom slots over the screw heads This al lows the weight of the ash pan to rest on the scr...

Страница 24: ...ighten lock nut Door handle needs to move smoothly E Calculating Alternate Floor Protection Material Thermal Conductivity k value The k value indicates the amount of heat in BTU s that will flow in 1...

Страница 25: ...of wet unseasoned wood resulting in wasted heat Do not over fire Over firing may ignite creosote or will damage the stove and chimney To prevent over firing your stove DO NOT Use flammable liquids Ov...

Страница 26: ...function is performed by sliding the con trol all the way back until it stops at the HI indicator on the label and then pulling forward to the front of the stove until it stops This activates the ACC...

Страница 27: ...s air is regulated by the Burn RateAir Control There are four settings High Medium High Medium Low and Low When the control is raised all the way up it is on the High setting and when pushed all the d...

Страница 28: ...2mm in diameter Be careful not to smother the fire Stack the pieces of wood carefully near enough to keep each other hot but far enough away from each other to allow adequate air flow between them 7 S...

Страница 29: ...to improper baffle place ment is not covered by warranty Operate the wood burning appliance with the baffle in the correct position only Not doing so could result in Reduced efficiency Overheating th...

Страница 30: ...age 15 I Blower Operating Instructions WARNING Fire Risk DO NOT BURN GARBAGE OR FLAMMABLE FLUIDS SUCH AS GASOLINE NAPTHA OR ENGINE OIL Do NOT burn treated wood or wood with salt driftwood May generate...

Страница 31: ...nt pipe blockage poor draft and chimney fires Always burn dry wood to help prevent cap blockage and creosote build up Keeping the door and glass gasket in good shape will maintain good burn times on a...

Страница 32: ...hat before each heating season the entire system be professionally inspected cleaned and repaired if necessary a The stove and ashes must be completely cooled down before using the Ash Removal System...

Страница 33: ...lly available oven cleaner After using an oven cleaner it is advisable to remove any residue with a glass cleaner or soap and water Oven cleaner left on during the next firing can permanently stain th...

Страница 34: ...h retainer just a few turns until each is secured Check again for centering of glass in door frame Continue to tighten each retainer alternately a few turns at a time until the glass is secure DO NOT...

Страница 35: ...brick under clips on side of firebox and push the bottom of the brick until it is flush with the side of the appliance D Firebrick Replacement Use Part 832 0550 when ordering individual brick Provide...

Страница 36: ...top of baffle board open up and flatten and smooth out the blanket Re check the baffle board for correct positioning Figure 36 2 Figure 36 1 Baffle Figure 36 2 Ceramic Blanket F Snap Disc Replacement...

Страница 37: ...be channel assembly into side of firebox and insert each tube into the corresponding hole in the tube channel rack starting with the back hole first 3 Make sure tube channel assembly is flush against...

Страница 38: ...appliance towards the wind Wood condition is too wet too large Use dry seasoned wood refer to wood fuel sec tion Bed of coals not established before adding wood Start with paper kindling to establish...

Страница 39: ...Millennium Wood Stove Advanced Combustion Control ACC 3100 ACC Millennium Part number list on following page 31M ACC MBK 7 06 Active 31M ACC GT 7 06 10 06 31M ACC NT 7 06 10 06 Beginning Manufacturin...

Страница 40: ...2 Thick 19 W x 13 3 4 H 832 3390 Y 9 Baffle Board 9 1 2 in W x 13 3 4 in H Pkg of 2 SRV7033 209 Y 10 Brick Assembly Complete Set Pkg of 18 SRV7033 006 10 1 Brick 9 x 4 1 2 x 1 1 4 Qty 12 Req 10 2 Bric...

Страница 41: ...4 5 Rear Air Control Arm Assembly 7033 035 Y 14 6 Start Up Control Knob 7000 343 14 7 Air Control Rod Guide 7033 210 14 8 Latch Magnet For Air Control 229 0631 14 9 Timer Arm Assembly 7033 034 Y 14 10...

Страница 42: ...3 Y 17 5 Trim Ring Door Gold 430 2682 Nickel 430 5340 17 6 Door Glass Assembly 15 1 2 in W x 13 3 8 in H 7000 012 Y 17 7 Glass Frame Set 4 Pieces 832 0350 17 8 Cam Latch 430 1141 17 9 Key Cam Latch 43...

Страница 43: ...1 4 Trimount Plug Owners Manual and Warranty Card Black Gold Trim 7033 027 Nickel Trim 7033 029 Paint Touch Up 812 0910 Plug Trimount 250 Pkg of 24 229 0880 24 Y Door Handle Assembly 832 0540 Y Upgrad...

Страница 44: ...Service Parts 04 11 R Step Top Wood Stove 31ST ACC Advanced Combustion Control 3100 ACC Step Top Part number list on following page 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Beginning Manufacturing Date Sept 2...

Страница 45: ...k 4 1 2 x 4 1 2 x 1 1 4 Qty 2 Req 4 5 Brick 9 x 3 x 1 1 4 w angle see diagram Qty 1 Req Brick Uncut Pkg of 1 832 0550 Pkg of 6 832 3040 5 Tube Support Rack 7033 148 6 Brick Retainer 7033 149 7 Ceramic...

Страница 46: ...l 229 0631 14 9 Timer Arm Assembly 7033 034 Y 14 10 Timer Only Replacement Assembly SRV480 1940 Y 15 1 Ash Pan Assembly 7033 008 Ash Pan Leg ARS 7033 050 15 2 Legs Queen Anne Black 831 1240 Gold 831 1...

Страница 47: ...NUMBER 17 1 Door Assembly Black 832 1092 Gold Trim 832 1912 Nickel Trim DR 31 43NL 17 2 Hinge Pins 1 2 Gold Pkg of 2 832 0250 Nickel Qty 2 req 430 5320 17 3 Door Handle Assembly 832 0540 Y 17 4 Door H...

Страница 48: ...arranty Card Spring Handles in Door Assembly 7033 043 Component Pack Includes Touch Up Paint Spring Handles 1 1 2 and 2 1 4 Trimount Plug Owners Manual and Warranty Card Black Gold Trim 7033 027 Nicke...

Страница 49: ...July 7 2011 7033 277I Page 49 3100 Wood Stove Series ACC R E Service and Maintenance Log Date of Service Performed By Description of Service...

Страница 50: ...Page 50 7033 277I July 7 2011 R 3100 Wood Stove Series ACC F Warranty Policy...

Страница 51: ...July 7 2011 7033 277I Page 51 3100 Wood Stove Series ACC R...

Страница 52: ...hip purchased from Dealer phone Notes We recommend that you record the following pertinent information for your 3100 WOOD STOVE ACC DO NOT DISCARD THIS MANUAL CAUTION Important operating and maintenan...