16.Code Setting
108
16-2-6. High-Low Relative
Only when sampling is performed in the auto code up mode, High/Low Limit Judgments
can be made in the Relative mode by setting the High-Low Relative to "ON".
Setting item: ON / OFF
In the Relative mode, High/Low Limit Judgments are made as follows:
MODE
→
Code Set
→
Judgment: HI-LO Relative
Y
X
250
150
200
175
75
100
125
50
100
50
100
50
100
50
100
50
When the operation ch=0, since the reference value=0 at start-time,
high/low limit judgments are made with:
High Limit=100
Low Limit=50
When the operation ch=1, since the hold=75 on ch=0,
high/low limit judgments are made with:
High Limit=100
+
75
=
175
Low Limit= 50
+
75
=
125
When the operation ch=2 , since the hold=150 on ch=1,
high/low limit judgments are made with:
High Limit=100
+
150
=
250
Low Limit=50
+
150
=
200
When the operation ch=3 , since the hold=75 on ch=2,
high/low limit judgments are made with:
High Limit=100
+
75
=
175
Low Limit=50
+
75
=
125
Example of use of High-Low Relative:
When the High Limit Setting=100, and the Low Limit Setting=50
Operation ch 0
Operation ch 1
Operation ch 2
Operation ch 3
Code up point
on operation ch 0
Code up point
on operation ch 1
Code up point
on operation ch 2