Return format
:
Query returns {START | ID | DATA | ACKerror | BITFILL | IDDATA | END}.
For example
:
:SBUS:CAN:QUALifier ACK
Set CAN bus trigger condition to ACKerror.
:SBUS:CAN:QUALifier?
Query returns ACKerror.
:SBUS:CAN:FRAMe:TYPE
Command format
:
:SBUS:CAN:FRAMe:TYPE { DATA | REMote | OVERload | ERRor }
:SBUS:CAN:FRAMe:TYPE?
Functional description
:
This command is used to set CAN bus trigger frame type of the oscilloscope.
Return format
:
Query returns { DATA | REMote | OVERload | ERRor }.
For example
:
:SBUS:CAN:FRAMe:TYPE ERRor
Set CAN bus trigger frame type to ERRor.
:SBUS:CAN:FRAMe:TYPE?
Query returns ERRor.
:SBUS:CAN:ID:MODE
Command format
:
:SBUS:CAN:ID:MODE {STANdard | EXTended}
:SBUS:CAN:ID:MODE?
Functional description
:
This command is used to set ID identifier frame format of CAN bus of the oscilloscope.
Return format
:
Query returns {STANdard | EXTended}.
For example
:
:SBUS:CAN:ID:MODE STANdard
Set ID identifier frame format of CAN bus to STANdard.
:SBUS:CAN:ID:MODE?
Query returns STANdard.
:SBUS:CAN:ID
Command format
:
:SBUS:CAN:ID <string>
:SBUS:CAN:ID?
Functional description
:
This command is used to set
ID identifier frame data of CAN bus of the oscilloscope. Set the corresponding
ID identifier according to the mode of
:SBUS:CAN:ID:MODE. Binary character string data presented by
parameter is 0, 1 or X. X represents unsure.
Standard frame range is 0x0~07FF, data bit occupies 11bits; Extend frame range is 0x0~0x1FFFFFFF, data