Programming Manual MSO/UPO2000 Series
133 / 156
Instruments.uni-trend.com
Return format
:
Query returns sweep point.
For example
:
:BODe:SWEep:POINts 1000
Set sweep point of bode diagram to 1000.
:BODe:SWEep:POINts?
Query returns 1000.
:BODe:SWEep:FREQuency:STARt
Command format
:
:BODe:SWEep:
FREQuency:STARt <freq>
:BODe:SWEep:
FREQuency:STARt?
Functional description
:
Set sweep start frequency of bode diagram.
Return format
:
Query returns sweep start frequency of bode diagram, unit is Hz.
For example
:
:BODe
:SWEep
:FREQuency:STARt 1 kHz
Set
start frequency to 1 kHz.
:BODe
:SWEep
:FREQuency:STARt?
Query returns 1.000e003.
:BODe:SWEep:FREQuency:END
Command format
:
:BODe:SWEep:
FREQuency:
END
<freq>
:BODe:SWEep:
FREQuency:
END
?
Functional description
:
Set sweep cut-off frequency of bode diagram.
Return format
:
Query returns cut-off frequency of bode diagram, unit is Hz.
For example
:
:BODe
:SWEep
:FREQuency:END 1 kHz
Set cut-off frequency to 1 kHz.
:BODe
:SWEep
:FREQuency:END?
Query returns 1.000e003.
:BODe:AMPLitude:MODE
Command format
:
:BODe:AMPLitude:MODE
{ FIXed | VARiable }
:BODe:AMPLitude:MODE
?
Functional description
:
This command is used to set amplitude mode of bode diagram.
FIXed represents the amplitude mode is
fixed; VARiable represents the amplitude mode is variable.
Return format
:
Query returns
{ FIXed | VARiable }
.
For example
:
:BODe:AMPLitude:MODE
FIXed
Set amplitude mode of bode diagram to
FIXed.
:BODe:AMPLitude:MODE
?
Query returns
FIXed.