F Power Supply and Matching Box
56
7-1-2. Troubleshooting related to the matching box
Table 7-2. Matching box related troubleshooting list
No.
Trouble symptom
Cause
Corrective action
1
Matching cannot be
achieved at the usual
matching point after the
power is turned on.
Load conditions differ from
previous conditions.
Check the gas pressure,
substrate, etc.
Wiring in matching box is
disconnected.
Check the wiring.
Wiring from matching box to load
is grounded.
Check for traces of discharge on
the variable capacitors and the
wiring in matching box.
2
Reflected power (REF:Pr)
does not decrease.
Insufficient matching adjustment
See "5-3 Matching adjustment"
and adjust matching.
Not discharging.
Check the discharge conditions
like gas pressure, etc.
3
Variable capacitors not
operating in manual mode.
Auto matching controller problems
Contact ULVAC.
Mechanical problems
Check the coupling connecting the
variable capacitors and motor to
see if it slides.
Electrical problems
Contact ULVAC.
Cable break or poor connector
contact
Retighten the connector screws.
Purchase a new cable if broken.
4
Matching does not start in
auto mode. (Does not
operate.)
Configuration mistake
For local operation, set to AUTO.
For remote operation, open pins
1-9.
Auto matching controller problems
Contact ULVAC.
Содержание RFS-13100F
Страница 66: ...F Power Supply and Matching Box 58 Figure 8 1 RFS 13100F...
Страница 67: ...F Power Supply and Matching Box 59 Figure 8 2 RFS 13150F ESC ENT M8...
Страница 68: ...F Power Supply and Matching Box 60 M8 60Kg Figure 8 3 RFS 13200F...
Страница 69: ...F Power Supply and Matching Box 61 Figure 8 4 RFS 27400F...
Страница 70: ...F Power Supply and Matching Box 62 Figure 8 5 MBX 13100F...
Страница 73: ...F Power Supply and Matching Box 65 Figure 8 8 MBX 27400F 2 M6...