RF Power Supply and Matching Box
2. Overview
6
Classification Item
Specification value
RFS-13200F
Input
Phase, frequency
Three-phase 50/60 Hz
Input voltage
400/440/480 VAC
Fluctuation range
±10% (360 V to 528 V)
Input capacity
32 kVA or less
Connector
N/MS3102A32-17P
Leakage current
5 mA or less
Output
Oscillation frequency
13.56 MHz ± 0.05%
Rated traveling wave
power
20 kW (at 50 Ω load)
Maximum reflected wave
power
2000 W
Output impedance
50 Ω
Harmonic distortion
-45 dB or lower (in continuous mode at rated output)
Power stability
±3% or less of rated power (10% to 100% of rated power)
Rise time
200 ms minimum
Linearity
±2 % or less of rated power (10% to 100% of rated power)
Output connector
EIA 1-5/8
Cooling
Cooling method
Water-cooled
Water temperature
5°C to 25°C (no condensation)
Water volume
8 L/min or higher (* Alarm operates at cooling water volume
7.5 L/min or lower)
(However, the alarm does not operate when RF-OFF)
Differential pressure
Approx. 0.07 MPa (at 8 L/min)
Withstand pressure
0.96 MPa or less
Joint
PT-3/8
Water quality
See "RF system cooling water - Water quality"
Exterior
Exterior dimensions
480 W x 350 H x 660 D
Configuration
Rack mount configuration
Weight
Approx. 60 kg
Table 2-2 RF power supply individual specifications
Содержание RFS-13100F
Страница 66: ...F Power Supply and Matching Box 58 Figure 8 1 RFS 13100F...
Страница 67: ...F Power Supply and Matching Box 59 Figure 8 2 RFS 13150F ESC ENT M8...
Страница 68: ...F Power Supply and Matching Box 60 M8 60Kg Figure 8 3 RFS 13200F...
Страница 69: ...F Power Supply and Matching Box 61 Figure 8 4 RFS 27400F...
Страница 70: ...F Power Supply and Matching Box 62 Figure 8 5 MBX 13100F...
Страница 73: ...F Power Supply and Matching Box 65 Figure 8 8 MBX 27400F 2 M6...