OPERA
TION
Operation with Touch Screen
The touch screen control panel allows the user more options than the digital control panel.
The embedded microprocessor controls each sequence of the packaging operation. Settings
for the vacuum, gas, and sealing are entered as parameters through the keypad. This
allows the user to custom program every step of the packaging process. The precise vacuum
and gas pressures are controlled by a pressure based sensor. The vacuum pressure, gas
pressure, and seal time are displayed on a large 4.3” LCD touch screen, which can be read
easily in all lighting conditions. As each sequence is performed, the real-time pressure level
or cycle time is displayed.
The touch screen panel can save up to 99 pre-programmed routines, which can be retrieved
at any time for specific packaging applications. [With the supervisor security feature turned
on, these programs cannot be inadvertently changed.]
The VACPLUS option allows the operator to run the pump from .1 to 6 seconds after the set
vacuum level is achieved.
The Gas Flush option allows the operator to introduce an inert gas into the chamber after
the vacuum stage. This option can be used as a filler to prevent crushing of the product
after sealing, as a means to prolong shelf life or as a means to maintain desirable product
appearance.
The touch screen panel has an auto stop, which will automatically seal if the preset vacuum
is not reached. This feature decreases the cycle time and optimizes the vacuum level of each
product.
The touch screen panel meets or exceeds the requirements of NEMA 4. The front of the
touch screen is sealed and flush mounted for easy cleaning.
The touch screen has both pulsed vacuum and pulsed venting options for fragile product.
The touch screen has a maintenance screen for testing valves and a special loop option for
multiple vacuum/gas cycles before sealing.
Figure 3.4
Содержание ULTRAVAC 2100
Страница 2: ......
Страница 81: ......
Страница 90: ...9 ...
Страница 91: ...10 ...
Страница 93: ...12 13 ...
Страница 101: ...21 Maximum oil temperature with 80 F ambient temperature and no supplemental oil cooling ...
Страница 102: ...22 ...
Страница 105: ......
Страница 120: ...RA 0165 0205 0255 0 0305 D Ref BMC Dwg T111 911 728 D 15 Fig 5 Exploded View Drawing of Pump ...