THE NEW STANDARD FOR
INNOVATION
• [email protected] • UltraSourceUSA.com
UltraSource LLC • 1414 West 29th Street • Kansas City, MO 64108-3604 USA • 800.777.5624 • 816.753.2150
4.7
MAINTENANCE
Supervisor Menu on Digital Panel
Untrained personnel should not alter any setting in the supervisor menu.
Figure 4.6
WAITTIME: 4
CUTTIME: 1.5
PREVAC: 25
RUNNING PROG: 1
NO
YES
PROGRAM
NO
YES
PROGRAM
NO
YES
PROGRAM
NO
YES
PROGRAM
-
+
-
+
-
+
-
+
This is the main menu screen. When
the machine starts up, the last program
that was run will be the current program
shown in the window.
Press and hold down both arrow keys for
at least 3 seconds to enter the supervisor
menu.
NOTE:
If your machine is not installed
with the precut option, disregard the
PREVAC, CUTTIME, and WAITTIME
parameters.
PREVAC is the % vacuum that you wish to
reach before activating the knife, which
makes slits in the bag for precut. Use the
up or down arrow keys to change the
current setting.
The range is from 5% to 20% vacuum.
Press the MENU key.
CUTTIME is the number of seconds that
the seal valve is activated. This is the
time when the knife actually makes the
evacuation slits in the bag/pouch for
precut. The range is from 0 to 3 seconds.
Press the MENU key.
WAITTIME is the number of seconds the
machine waits for the knife to retract
before resuming the vacuum cycle. The
range is from 0 to 6 seconds.
Press the MENU key.
The following are parameters that can
only be set in the supervisor menu.
Содержание ULTRAVAC 2100
Страница 2: ......
Страница 81: ......
Страница 90: ...9 ...
Страница 91: ...10 ...
Страница 93: ...12 13 ...
Страница 101: ...21 Maximum oil temperature with 80 F ambient temperature and no supplemental oil cooling ...
Страница 102: ...22 ...
Страница 105: ......
Страница 120: ...RA 0165 0205 0255 0 0305 D Ref BMC Dwg T111 911 728 D 15 Fig 5 Exploded View Drawing of Pump ...