MAINTENANCE
EXIT GAS: YES
LOOP #: 1
NO
YES
PROGRAM
NO
YES
PROGRAM
-
+
-
+
VAC TIMEOUT: ON
NO
YES
PROGRAM
-
+
If the machine is equipped with the LOOP
option, this is the number of vacuum/gas
cycles the control will perform prior to the
seal and vent.
The range is 1 to 5 cycles.
The default value is 1 cycle.
Press the MENU Key.
If the Loop # is set greater than 1, the
control can be set to exit this loop on either
the last gas cycle or the last vacuum cycle
prior to sealing.
The DOWN arrow key indicates NO.
The UP arrow key indicates YES.
Press the MENU Key.
VAC TIMEOUT is an option that is turned
ON or OFF. If set OFF, default, the machine
will time out if the preset vacuum is not
reached in 6 seconds, and the machine
will complete the cycle. If set ON and the
machine does not reach the preset vacuum
in thirty seconds, then the panel will display
VAC ERROR and vent the chamber without
sealing.
Supervisor Menu on Digital Panel
Figure 4.10