THE NEW STANDARD FOR
INNOVATION
• [email protected] • UltraSourceUSA.com
UltraSource LLC • 1414 West 29th Street • Kansas City, MO 64108-3604 USA • 800.777.5624 • 816.753.2150
ST
ARTUP
2.1
STARTUP
Unpacking
1. Carefully remove crate from the skid.
2. Remove machine from skid.
3. Wipe down outside of the machine.
Power Requirements
The machine is available with a 7½ horsepower vacuum pump for the 200mm (8-in.) model
and a 10 horsepower vacuum pump for the 300mm (12-in.) model. The standard machine
is rated 220 volt, 60 Hertz, 3 phase and is supplied with a 30 amp, 250 volt, 3 phase plug.
The owner must supply the correct 3 phase or single phase power source in accordance
with the National Electric Code. The table below is based on the National Electric Code and
is to be used as a guide in wire size selection and short circuit protection. The requirements
noted in the table may change. Please consult an electrician prior to installation.
UV2100 POWER CABLE SIZING CHART
208/230v (5&7.5hp Pumps)
10 gauge/ 4 conductor
380v
12 gauge/ 5 conductor
460v
10 gauge/ 4 conductor
208/230v (10&12hp Pumps)
8 gauge/ 4 conductor
380v w/o neutral
12 gauge/ 4 conductor
Customer Voltage
Pump Motor Full Load Amps
Supply conductor shall
Supply conductor shall
have an ampacity not
have an ampacity not
less than 125% of the
less than 125% of the
Pump Motor Full Load
Pump Motor Full Load
Amps
Amps
5 HP 7.5 HP
10 HP
12 HP
208, 60 Hz 3 Phase
21
26.5
32
230, 60 Hz 3 Phase
20.5
26
30
380, 50 Hz 3 Phase
12
14
15
460, 60 Hz 3 Phase
10.5
13
15
575, 60 Hz 3 Phase
9
10.5
12.5
230, 60 Hz Single Phase
22.5
-
-
-
Customer Voltage
Inverse Time Circuit
Breaker
Fused Disconnect Dual
Element (Time Delay)
5 HP 7.5 HP 10 HP 12 HP 5 HP 7.5 HP 10 HP 12 HP
208, 60 Hz 3 Phase
50
60
70
35
45
50
230, 60 Hz 3 Phase
50
60
60
35
45
50
380, 50 Hz 3 Phase
25
30
35
20
20
25
460, 60 Hz 3 Phase
25
30
35
15
20
25
575, 60 Hz 3 Phase
20
25
30
15
15
20
230, 60 Hz Single Phase
60
-
-
-
45
-
-
-
Содержание ULTRAVAC 2100
Страница 2: ......
Страница 81: ......
Страница 90: ...9 ...
Страница 91: ...10 ...
Страница 93: ...12 13 ...
Страница 101: ...21 Maximum oil temperature with 80 F ambient temperature and no supplemental oil cooling ...
Страница 102: ...22 ...
Страница 105: ......
Страница 120: ...RA 0165 0205 0255 0 0305 D Ref BMC Dwg T111 911 728 D 15 Fig 5 Exploded View Drawing of Pump ...