3.3
OPERA
TION
Operator Menu on Digital Panel
NOTE:
if the supervisor has set security on, these settings cannot be changed.
Figure 3.5
VACPLUS: 4.0
SEAL: 1.2
VACUUM: 98
RUNNING PROG: 1
NO
-
+
PROGRAM
YES
-
NO
YES
PROGRAM
+
NO
-
YES
+
PROGRAM
YES
PROGRAM
+
-
NO
This is the Main Menu screen. When
the machine starts up, the last program
that was run will be the current program
shown in the window. To set the operating
parameters for the program shown press
the MENU Key.
VACUUM is set to % vacuum using the UP
and DOWN arrow keys. The range is 30%
to 99%.
Press the MENU Key.
VACPLUS may be set greater than zero
to allow the pump to continue evacuating
the chamber (for the specified number
of seconds) after the pressure in the
chamber has reached the % vacuum set
in the vacuum menu. The range is 0 to 20
seconds.
Press the MENU Key.
The SEAL setting is in seconds.
Use the UP and DOWN arrow keys to
change the seal time. The range is 0 to 2
seconds.
Press the MENU Key.