MAINTENANCE
MAINTENANCE
Prior to Cleaning
Every environment and application is different; therefore, UltraSource LLC cannot provide
cleaning instructions to guarantee microbiological sanitation. UltraSource requests that the
owner of this machine consult with sanitation experts to review the unit working in their
particular environment to develop a robust cleaning schedule and methodology, followed by
bacterial testing to ensure satisfactory cleaning procedures are followed.
Cleaning Recommendations
Before cleaning the machine, turn power off; disconnect the main power, and lockout the
connection.
DANGER
Hazardous voltage.
Disconnect and lockout power before servicing machine or cleaning. Do not remove panels
unless power has been disconnected and locked out at risk of electric shock hazard.
Check with the detergent and sanitizer manufacturers that their products are compatible
with the listed materials.
CAUTION
CAUTION
Cleaning agents.
Do not get the cleaning agents in eyes, on skin, or on clothing. Always wear rubber gloves,
goggles, and protective clothing when contact is likely. Consult product manufacturer for
specific details.
Never hose down the machine. Damage caused by hosing or high pressure washing is not
covered under warranty.
1.
Filler Plates:
Remove filler plates. The filler plates are made from polyethylene. Clean,
sanitize, and dry. High pressure water spray can be used on the filler plates.
2.
Lid, Chamber, and Base:
These components are made of aluminum. Clean the lid,
chamber, base, and silicone seal backup strip with a non-ionic cleaning solution such
as Crystal Simple Green.
3.
Seal Bars:
Remove the seal bars. The seal bars are made of phenolic. Clean, sanitize,
and dry. Also clean under the seal bar bladder in the lid, which is not removable.
4. Clean under the machine.
5. Reinstall the seal bars.
6. Use bacteriological testing to insure cleaning process.
WARNING
WARNING
Electrical Supply Cord.
The supply cord must be replaced by an Ultravac Services Service Technician or similarly
qualified person in order to avoid hazard.
Содержание ULTRAVAC 2100
Страница 2: ......
Страница 81: ......
Страница 90: ...9 ...
Страница 91: ...10 ...
Страница 93: ...12 13 ...
Страница 101: ...21 Maximum oil temperature with 80 F ambient temperature and no supplemental oil cooling ...
Страница 102: ...22 ...
Страница 105: ......
Страница 120: ...RA 0165 0205 0255 0 0305 D Ref BMC Dwg T111 911 728 D 15 Fig 5 Exploded View Drawing of Pump ...