4.5
MAINTENANCE
Troubleshooting
Problem
Indications
Remedy
Machine will not start
Green power “ON” light not
lit when switch is turned on
Make sure that the power
requirements match those given
on the nameplate. Also, check
fuse F-3; replace if blown.
Vacuum pump does not run
Make sure that the power
requirements match those given
on the nameplate. Also, check the
overload OL-1; reset if necessary.
No vacuum
When lid is closed, indicator
light (VAC) is “OFF” on the
control module
Check lid switches LS-1 and LS-2
for proper adjustment
Vacuum not pulling lid down
on both sides
Check intake screen in vacuum
pump hose barb for blockage,
pieces of bags, labels, bone, etc.
Longer vacuum cycle times
Check intake screen in vacuum
pump hose barb for blockage
No gas flush (optional) If indicator light (GAS) is lit
Check for proper gas pressure
going into gas inlet
If indicator light (GAS) is not
lit
Check for proper operation of gas
flush valve (SOL-2)
possible defective control module
Gas flushes to one chamber
side only
Check gas flush selector valve
(V-1) for proper adjust
Chamber not venting
(lid will not open)
Lid will not open and red
indicator light “VENT” on
control module is lit
Check ventilation valve SOL-4 for
proper operation
“VENT” indicator light is not
lit
possible defective control module
NOTE:
Lid can be released by pulling the hose off of
the vacuum gauge to remove product.
Содержание ULTRAVAC 2100
Страница 2: ......
Страница 81: ......
Страница 90: ...9 ...
Страница 91: ...10 ...
Страница 93: ...12 13 ...
Страница 101: ...21 Maximum oil temperature with 80 F ambient temperature and no supplemental oil cooling ...
Страница 102: ...22 ...
Страница 105: ......
Страница 120: ...RA 0165 0205 0255 0 0305 D Ref BMC Dwg T111 911 728 D 15 Fig 5 Exploded View Drawing of Pump ...