If the gas that is pumped contains dust or other
foreign solid particles, a suitable (10 micron rating
or less) inlet filter should be connected to the inlet
port. Consult the factory for recommendations.
1.5 Oil Filling
The pump is shipped without oil. After level
installation, and after correct rotation has been
established, fill the pump with the recommended
vacuum oil through the oil filling port (Ref. 88),
observing the "MAX" and "MIN" position at the oil
sight glass (Ref. 83).
Non-detergent oil should be used.
Do not use
detergent motor oil
as additives in detergent oil
will plug exhaust filter elements and shorten their
life.
It is recommended that Busch R500 Series oil be
used to receive the best performance from your vac-
uum equipment. R500 Series oil is a high quality
vacuum oil which will give longer running time
between oil changes, will provide better lubrication
at high operating temperatures, and will prolong the
life of exhaust filter elements. This oil can be
obtained directly from Busch, Inc. in Virginia
Beach, Virginia.
The strict use of Busch oils and parts from the
day of purchase can extend the standard warranty to
three years. Contact Busch, Inc. in Virginia Beach,
Virginia for details. Refer to page 20 for the standard
warranty.
For general applications, use R530 in most mod-
els. Use R590 or R570 in pumps that are operated
in high ambient temperatures (above 90°F) or high
operating pressure when the oil carbonizes (turns
black) before the change interval. Use R590 or R570
on 0250 pumps. Contact the factory for recommen-
dations when using other oils.
The following table gives the approximate quan-
tities of oil required for each pump:
Pump Type
Oil Capacity (Qt.)
0025/0040
1.4
0063/0100
2.5/2.7
0250
7
The oil capacity chart should only be used as a
guide, since oil capacity may be slightly lower,
depending on whether the pump was filled previ-
ously, and whether all components such as oil filter,
oil lines, etc., were allowed to completely drain. Use
only the sight glass reading for proper level. Never
overfill.
For ambient operating temperatures lower than
41°F, use Busch R580 synthetic oil. If this does not
help (where the pump has difficulty starting due to
high oil viscosity) contact the factory in Virginia
Beach, Virginia.
Replace the oil fill plug (Ref. 88/90), making
sure that the gasket (Ref. 89) is in place and proper-
ly seated and secured. Some pumps are equipped
with an exhaust pressure gauge as an integral part of
the oil fill plug.
2.0 OPERATION
2.1 Start-up
Check rotation of the motor as described in para-
graph 1.3 - Power Requirements.
Fill the pump with oil as described in paragraph
1.5 - Oil Filling.
Start the pump and immediately close the inlet.
Run the pump for a few minutes before checking the
oil level again. With the pump shut off, the oil level
should be visible in the oil sight glass (Ref. 83),
between the "MIN" and "MAX" mark.
Add oil, if necessary, but only add it when the
pump has been shut off and the circulating oil has
Caution: When using PVC pipe or any static
enhancing material for the exhaust piping, make
provisions to safeguard against arcing from stat-
ic electricity. Arcing can ignite oil vapor that
may be present.
Warning: Keep the oil fill plug tight as pres-
sure in the exhaust box could cause bodily injury
if the plug is blown out. Do not fill/add the pump
with oil through the exhaust/inlet ports as there
is danger of breaking the vanes!
4
Содержание ULTRAVAC 2100
Страница 2: ......
Страница 81: ......
Страница 90: ...9 ...
Страница 91: ...10 ...
Страница 93: ...12 13 ...
Страница 101: ...21 Maximum oil temperature with 80 F ambient temperature and no supplemental oil cooling ...
Страница 102: ...22 ...
Страница 105: ......
Страница 120: ...RA 0165 0205 0255 0 0305 D Ref BMC Dwg T111 911 728 D 15 Fig 5 Exploded View Drawing of Pump ...