THE NEW STANDARD FOR
INNOVATION
• [email protected] • UltraSourceUSA.com
UltraSource LLC • 1414 West 29th Street • Kansas City, MO 64108-3604 USA • 800.777.5624 • 816.753.2150
4.4
MAINTENANCE
Reading the Indicators
All machines are controlled by an analog control module (with knobs) or a digital control
module (with touch pad) designed to aid in troubleshooting. The analog control module,
mounted behind the front control panel, has five red indicator lights (LEDs) mounted to it.
To view the indicator lights on the analog control module during operation remove the six
screws on the front of the control panel and pull the control panel out. The digital panel
has indicator lights mounted on the front below the ON/OFF switch. The indicator lights
correspond to the operating devices and should turn on and off in the following sequence
when the machine lid is closed:
1.
Vacuum Valve [SOL-1]
2.
Gas Flush Valve [SOL-2] (Optional)
3.
Seal Bladder Valve [SOL-3]
(Stays on until completion of cycle)
4.
Seal Impulse Contractor [C-2]
5.
Ventilation Valve [SOL-4]
The device should be operating when the LED is illuminated. If the LEDs illuminate in the
proper sequence, but there is still a problem, look for the problem in the operating device
itself. If the LEDs do not sequence properly, look for a problem in the related potentiometer
or the control module.
1. VACUUM VALVE [SOL-1]
2. GAS FLUSH VALVE [SOL-2] (OPTIONAL)
3. SEAL BLADDER VALVE [SOL-3]
(STAYS ON UNTIL COMPLETION OF CYCLE)
4. SEAL IMPULSE CONTACTOR [C-2]
5. VANTILATION VALVE [SOL-4]
Содержание ULTRAVAC 2100
Страница 2: ......
Страница 81: ......
Страница 90: ...9 ...
Страница 91: ...10 ...
Страница 93: ...12 13 ...
Страница 101: ...21 Maximum oil temperature with 80 F ambient temperature and no supplemental oil cooling ...
Страница 102: ...22 ...
Страница 105: ......
Страница 120: ...RA 0165 0205 0255 0 0305 D Ref BMC Dwg T111 911 728 D 15 Fig 5 Exploded View Drawing of Pump ...