2.3 System start

First  of  all  supply  the  system  with  power  by  means  of  the  thermal  switch  located  on  the  power  cord.  The
switch  must  be  set  to  the  ON  position  (switch  closed).  If  there  are  two  power  cords  and,  therefore,  two
thermal  switches,  make  sure  that  both  of  them  are  set  to  the  ON  position.

2.3.1 System power supply

To  correctly  start  the  system,  follow  the  steps  below:

The  panel  keys  of  the  engine  of  each  boat  must  be  enabled.

When  the  engine  panel  key  contact  is  closed  (key  enabled)  the  control  station  signals  to  the  user  that  the
boat  can  be  controlled  with  a  LED  flashing  and  an  intermittent  sound  signalling.

In  single-engine  boats,  the  flashing  LED  is  the  one  shown  in  the  picture  aside.
The  same  occurs  in  twin-engine  boats,  if  the  port  engine  key  is  enabled.
During this condition the system cannot be controlled: any lever movement has
no  effects  on  the  engine;  therefore,  pressure  on  trim  switches  is  ignored.

In  twin-engine  boats,  if  the  starboard  engine  key  is  enabled,  the  flashing  LED
will  show  that  the  starboard  station  has  been  enabled  (see  picture  aside).
In  this  case  too,  the  system  cannot  be  controlled.

In  twin-engine  boats,  when  both  engine  keys  are  enabled,  both  LEDs  will  flash
showing  that  the  station  has  been  enabled,  as  shown  in  the  picture  aside.
In  this  case  too,  the  system  cannot  be  controlled.

If  the  engine  key  is  disabled  and  the  control  is  waiting  for  the  station  enabling,
the  relevant  LED  will  switch  off  showing  that  the  relevant  side  is  disabled.

2.3.2 Panel key enabling

Содержание Power A Mark II

Страница 1: ...PARTNER ITA LIAN O Dr No 28394 a 16 02 2015 ELECTRONICCONTROLSYSTEM R ENGLISH Owner smanual ...

Страница 2: ... customer maintain and improve the quality standards constantly pursue a continuous process improvement to meet the market needs and to increase the customer satisfaction ULTRAFLEX Environmental Management System is certified CISQ IQNet by the Italian Shipping Registry RINA in conformity with the UNI EN ISO 14001 rule ULTRAFLEX certification No EMS 1282 S Products for pleasure boats are constantly...

Страница 3: ...E 14 2 4 2 AUTOSYNC MODE 15 2 4 3 HIGH IDLE MODE 16 2 4 4 TROLL MODE 17 2 4 5 DOCKING MODE 18 2 4 6 PANEL BRIGHTNESS ADJUSTMENT 19 SECTION3 WARNINGSANDALARMS 3 1 CONTROL STATION 21 3 2 V THROTTLE I THROTTLE PWM THROTTLE SAEJ THROTTLE 23 3 3 SHIFT UNIT 24 3 4 MECHANICAL ACTUATOR USED AS THROTTLE 26 3 5 MECHANICAL ACTUATOR USED AS SHIFT 28 3 6 CONTROL UNIT 30 SECTION 6 DISMANTLING 6 1 DISMANTLING 34...

Страница 4: ...Owner smanual ULTRAFLEX page 4 of 36 POWER A MK2 ENGLISH DOCUMENT REVISIONS Rev Date Revision description 0 02 09 2011 First edition ...

Страница 5: ...eaning of some nautical words contained in this manual DANGER Immediate hazards which CAUSE severe personal injury or death WARNING CAUTION The symbol aside indicates all the operations which must be carried out by qualified or skilled staff in order to avoid hazards We recommend training the staff in charge of the product installation and checking their knowledge NOTICE Important information for ...

Страница 6: ...ied including not in a restricted way the suitability warranty for any special purpose Nothing contained in this manual can be interpreted as a modification or confirmation of the terms of any purchase contract To ensure the correct product and component working the product must be installed by qualified staff In the event of part damage or malfunction please contact the qualified staff or our Tec...

Страница 7: ...boat The trims to control the attitude stabilizers can be located on the port lever the only one in case of single engine boats CONTROL STATION TWIN ENGINE WITHTRIM TWIN ENGINE WITHOUT TRIM SINGLE ENGINE WITHTRIM SINGLE ENGINE WITHOUT TRIM CONTROL UNIT The boat can be equipped with maximum four control stations the user will be allowed by the system to control the boat using only one station at a ...

Страница 8: ...t analogue interface are provided with the I throttle unit which is externally identical to the V throttle unit V THROTTLE UNIT If the throttle is provided with a CAN bus digital interface a SAEJ throttle or a NMEA throttle unit must be used SAEJ THROTTLE UNIT In case of electric shifts a shift unit allowing the gear solenoid control is used SHIFT UNIT The power unit has the function of supplying ...

Страница 9: ...Enabling and disabling of throttle mode in neutral position 3 Key HIGH IDLE Enabling and disabling of the high idle and alarm silencing 4 Key SYNC Enabling and disabling of the engine revolution synchronizing and docking modes A GREEN LED Enabling of the port station or single engine B RED LED Enabling of the throttle mode in neutral position for the port engine or single engine Failure signalling...

Страница 10: ... to a maximum value REVERSE GEAR Full speed 8 0 8 0 15 15 NEUTRAL When the lever is in central position the engine is in neutral and at idle DETENT FORWARD When the lever has a forward inclination of 15 the relevant shift is enabled and puts into forward gear The throttle remains at idle DETENT REVERSE When the lever has a reverse inclination of 15 the relevant shift is enabled and puts into forwa...

Страница 11: ...single engine boats the flashing LED is the one shown in the picture aside The same occurs in twin engine boats if the port engine key is enabled During this condition the system cannot be controlled any lever movement has no effects on the engine therefore pressure on trim switches is ignored In twin engine boats if the starboard engine key is enabled the flashing LED will show that the starboard...

Страница 12: ... start inhibition is ensured only if the proper switches have been connected as indicated in the installation manual NOTA NOTICE DANGER 2 3 4Controlenabling To control the system it is necessary to enable the required control station To carry out this operation push key CTRL once if the following conditions are met 1 The lever must be in neutral position 2 The panel key must be enabled 3 No failur...

Страница 13: ...t its own alarm code with a different sound sequence The display on the control unit will provide the user with more information about the kind of alarm enabled If more control stations are installed on the boat it is possible to use only one station at a time therefore only one control station at a time can be enabled To change station keep key CTRL pressed for a few seconds to disable the contro...

Страница 14: ...dentally start the engine which is not in WARM UP mode The WARM UP mode turns off when the controlled station is disabled and it does not turn on when the station is enabled again To disable the WARM UP mode the following conditions must be met The lever must be in neutral position There must be no failures that could prevent this mode from being disabled To disable the WARM UP mode press key WARM...

Страница 15: ...ms only This mode can be enabled if at least one station is controlled regardless of the lever position by pressing key SYNC on the user interface The green SYNC LED will light up without flashing indicating that this mode has been enabled Under this condition the engine synchronization occurs if the following requirements are met The difference in inclination between the levers is lower than 15 T...

Страница 16: ...e just press the proper key on the user interface The proper red LED will light up indicating that the HIGH IDLE mode is on In the engine acceleration curve the high idle value is set as the idle speed To disable the HIGH IDLE mode press the proper key on the user interface the HIGH IDLE red LED switches off when this mode is disabled In a twin engine system the HIGH IDLE mode can be enabled on on...

Страница 17: ...s that could prevent this mode from being enabled To enable the TROLL mode keep key HIGH IDLE pressed for a few seconds The mode is enabled when the key is released The proper green LED will blink indicating that the TROLL mode is on To disable the TROLL mode keep the proper key on the user interface pressed for a few seconds the TROLL green LED will switch off In a twin engine system the TROLL mo...

Страница 18: ...ent this mode from being enabled To enable the DOCKING mode keep key SYNC pressed the mode will be enabled when the key is released The proper red LED will light up indicating that the DOCKING mode is on In the engine acceleration curve the maximum engine speed is set as half of the normal speed To disable the DOCKING mode press the proper key on the user interface for a few seconds the DOCKING re...

Страница 19: ... to the maximum value By keeping the key pressed the brightness will be reduced to the minimum then increased again until the key is released To change the LED brightness it is not necessary to enable the station The LED brightness will be changed only on the station which was controlled by means of key WARM The new brightness value will be mantained until the system is switched off by means of th...

Страница 20: ...ror code on the control unit display The error is shown on the diagnostic main page In single engine systems if there are no errors this page is displayed as follows If there is an error indication ER is displayed as follows In twin engine systems if there are no errors this page is displayed as follows If there is an error indication ER is displayed as follows Indication ER can be present on one ...

Страница 21: ...message of the starboard shift Check the CAN bus connection or the power cord of the unit controlling the shift 7 Miss acc msg stbd The system has detected the lack of CAN message of the starboard throttle Check the CAN bus connection or the power cord of the unit controlling the throttle 8 Miss disp msg stbd The system has detected the lack of CAN message of the starboard control unit Check the C...

Страница 22: ... 14 Pll fault Problem in the control station processor Contact the technical assistance service to replace the control station 15 Miss parameters Problem in the control station processor Contact the technical assistance service to replace the control station ...

Страница 23: ...6 Miss disp msg stbd The system has detected the lack of CAN message of the starboard control unit Check the CAN bus connection 7 Miss troll msg stbd The system has detected the lack of CAN message of the starboard troll Check the CAN bus connection or the power cord of the unit controlling the trolling valve 8 Miss head msg stbd The system has detected the lack of CAN message of the starboard con...

Страница 24: ...ction reliability and the suitability of the solenoid valve 7 Nt fbk fault port The system has detected a problem on the neutral solenoid valve if it is used port or single engine Check the connection reliability and the suitability of the solenoid valve 8 Miss acc msg stbd The system has detected the lack of CAN message of the starboard throttle Check the CAN bus connection or the power cord of t...

Страница 25: ...harge 16 Ecc fault Problem in the shift unit processor Contact the technical assistance service to replace the shift unit 17 Watchdog fault Problem in the shift unit processor Contact the technical assistance service to replace the shift unit 18 Pll fault Problem in the shift unit processor Contact the technical assistance service to replace the shift unit 19 Miss parameters Problem in the shift u...

Страница 26: ...roblem on the actuator power sensor Contact the technical assistance service to replace the actuator 7 Sensor I fault The system has detected a problem on the actuator current sensor Contact the technical assistance service to replace the actuator 8 Over I fault The system has detected an excessive current absorption of the actuator Check if the mechanical cable is intact and free to slide 9 Brown...

Страница 27: ...Then turn off and on the system by means of the thermal switches 15 Warning underV The system has detected a low feeding on the mechanical actuator Performances are not changed Check the battery charge 16 Warning position The system has detected that the actuator shaft is placed at more than 1 5 mm from the desired position target Check if the mechanical cable is free to slide and if there is exce...

Страница 28: ...roblem on the actuator power sensor Contact the technical assistance service to replace the actuator 7 Sensor I fault The system has detected a problem on the actuator current sensor Contact the technical assistance service to replace the actuator 8 Over I fault The system has detected an exceeding current absorption of the actuator Check if the mechanical cable is intact and free to slide 9 Brown...

Страница 29: ...hat the actuator shaft is placed at more than 1 5 mm from the desired position target for the forward gear Check if the mechanical cable is free to slide and if there is excessive clearance 17 Warning rw position The system has detected that the actuator shaft is placed at more than 1 5 mm from the desired position target for the reverse gear Check if the mechanical cable is free to slide and if t...

Страница 30: ...ction or the power cord of the unit controlling the shift 6 Miss acc msg stbd The system has detected the lack of CAN message of the starboard throttle Check the CAN bus connection or the power cord of the unit controlling the throttle 7 Miss troll msg stbd The system has detected the lack of CAN message of the starboard troll Check the CAN bus connection or the power cord of the unit controlling ...

Страница 31: ...etected a problem of incompatibility among the different software versions of the components Contact the technical assistance service to replace the unsuitable components 14 Miss parameters Problem on the control unit processor Contact the technical assistance service to replace the control unit ...

Страница 32: ...o not disable the safety devices Do not modify or add devices to the system without ULTRAFLEX written authorisation or technical intervention which will prove the modification Do not use the equipment for a purpose different from the one it has been designed for which is specified in the installation and maintenance manual Do not let non specialized staff perform the installation DANGER WARNING Wh...

Страница 33: ...hanical actuator stems Cleaning operations 5 1 311 1 3Everythreemonths Every three months the following operations are required Check of the mechanical actuator calibrations Check of the mechanical actuator carriage tightening Greasing by using a marine lubrication of the mechanical actuator stems Cleaning operations 5 1 4Every year Every year Check possible damages or deterioration on the mechani...

Страница 34: ...H 6 DISMANTLING 6 1Dismantling When for any reason the system is put out of service it is necessary to follow some rules in order to respect the environment Sheaths pipelines plastic or non metallic components must be disassembled and disposed of separately ...

Страница 35: ...Owner smanual ULTRAFLEX ENGLISH POWER A MK2 page 35 of36 ENCLOSURES ...

Страница 36: ...ator Mounting of adapters on cables Mercruiser stern drive cable insert the two pressure bushes on the cable cylinder mount the cable on the locking system according to the procedure described in paragraph 6 4 of the Installation manual C2 C7 C8 and MACHZero cables follow the instructions described in paragraph 6 4 mount the cable on the locking system according to the procedure described in parag...