14
PWM off
The system has turned off the
actuator for precaution after a heavy
brownout.
Check the electrical connections
that feed the system, check the
battery charge. Then turn off and on
the system by means of the
thermal switches
15
Warning underV
The system has detected a low power
on the mechanical actuator.
Performances are not changed.
Check the battery charge.
16
Warning fw
position
The system has detected that the
actuator shaft is placed at more than
1,5 mm from the desired position
(target) for the forward gear.
Check if the mechanical cable is
free to slide and if there is
excessive clearance
17
Warning rw
position
The system has detected that the
actuator shaft is placed at more than
1,5 mm from the desired position
(target) for the reverse gear.
Check if the mechanical cable is
free to slide and if there is
excessive clearance
18
Warning neutral
position
The system has detected that the
actuator shaft is placed at more than
1,5 mm from the desired position
(target) for the neutral position.
Check if the mechanical cable is
free to slide and if there is
excessive clearance